Functional description
6.3.9
Standby temperature
6.3.10
Configuration mode
To enter the configuration mode, press and hold i-OP for two seconds when switching on
the soldering station.
Ersa i-CON 1V & i-CON 2V
1
The i-TOOL and CHIP TOOL VARIO can be reheated from standby tem-
perature by movement; the Tech-Tool and X-TOOL by briefly wiping with a
moist sponge; with all other tools by pressing or turning i-OP.
1
1
3BA00231 · 2019-03-12 · Rev. 4
This is the soldering tip temperature during work breaks.
It is automatically activated after the [Standby time] has
lapsed. Lowering the temperature saves energy and ex-
2
tends the tip and heating element service lives.
0
2
0
■
Turn i-OP to select a menu item, then press:
•
[CHANGE] opens the [Configuration] menu
•
[ABORT] stops the operation
•
[DEFAULT] restores the factory settings.
2
In the configuration mode the following settings are
possible:
0
0,5 s
•
Temperature window (monitoring)
•
Device number
•
Process alarm (audible temp. control)
•
Idle state
•
Password
•
Temperature unit
•
Activating the heating plate
2 s
2s
3
87
Need help?
Do you have a question about the i-CON 1V and is the answer not in the manual?
Questions and answers