Functional description
6.3.2.1

Setting three target temperatures (fixed temperatures)

You can set three fixed temperatures (target temperatures).
6.3.3

Calibration temperature

Ersa i-CON 1V & i-CON 2V
If you have activated the [Fixed temperature] function
in [Configuration mode], three temperature values
will appear in the working mode in the left half of the
display.
Select the desired temperature by pressing i-OP.
To open parameter mode, press and hold i-OP for
approx. 2 seconds.
Select the [Target temp.] parameter by turning i-OP.
Enable the cursor by pressing i-OP; select the desired
temperature.
End parameter mode You have now set the first fixed
temperature.
In working mode, select further temperatures by
pressing i-OP and set them in parameter mode as
described above .
This function serves the purpose of calibrating the solder-
ing tip temperature. It enables to balance the displayed
value and actual tip temperature. The adjustable calibra-
tion range is –70 - +50 °C / –126 - +90 °F.
The exact calibration procedure is described in chapter
6.3.5 [Calibration].
If you do not have an appropriate measuring instrument for this measure-
ment, please enter [0] into this parameter field.
3BA00231 · 2019-03-12 · Rev. 4