Functional description
6.3.2

Target temperature

The target temperature is the soldering tip temperature intended for work.
82
Separate the soldering tool from the soldering station
and connect the i-SET TOOL.
Turn i-OP and select the following: Upload: The station
data is written into the i-SET TOOL. Download: The
i-SET TOOL is written into the station. Then press i-OP.
A safety dialog appears:
Select [Cancel] to quit the process or [>>>] to continue.
Press i-OP; the settings will be saved. Wait until the
text [Parameter saved] appears in the display. Then
remove the i-SET TOOL.
Display contrast, calibration and offset are not transferred. When trans-
ferring data to the soldering station, the parameters for all soldering tools
will be overwritten. Please remember this when operating different tools
on your soldering station.
Even if the soldering station is equipped with a PC serial interface (option-
al), the device number is not transmitted to the station. With regard to
this, please read the [Device number] section!
3BA00231 · 2019-03-12 · Rev. 4
In working mode, the soldering tip temperature
of the enabled soldering tool can be directly
changed by turning i-OP. This is confirmed by
pressing i-OP.