SHIELD, WELDING ASSEMBLY (P/N 400102)
This procedure is to be performed only by personnel who have received appropriate training.
If you do not completely understand all of the procedure, contact Aqua Lung to speak directly
with a Technical Advisor before proceeding any further.
Part #
400087
400088
400089
400090
400035
400092
400093
400094
400095
400015
Step 1: Use a Phillips # 3 screwdriver
to remove three retainer port screws
(11) from top of helmet retainer port
(12).
Step 4: Secure and tighten left and
right hinge block mounting screws
(79) to 45 in.lbs (5 Nm).
APPENDIX I
INSTALLATION INSTRUCTIONS
KIT CONTENTS
Item Description
Body, Welding Shell (Shield)
Lens, Welding
Bracket, Lens Holding
Gasket, Welding Lens
Screw, Hex, Manifold
Hinge Block, Welding Lens
Screw, Hinge Block Mounting
Screw, Hinge
Shield, Welding Spring
Screw, Retainer Port
Step-by-Step Assembly Instructions
Step 2: Install shield welding spring
(78) and retainer port screw (11).
Tighten to 45 in.lbs (5 Nm).
Step 5: Secure and tighten left
and right hinge screws (80) to 45
in.lbs (5 Nm).
Qty per Kit
Step 3: Line up welding lens assembly.
Note: Hinge blocks (77)
and hinge block mounting
screws (79) pre-mounted
to shield.
Step 6: Confirm welding shield
opens and closes correctly.
69
1
1
2
1
2
2
2
2
1
1