MONTHLY INSPECTION AND MAINTENANCE CHECKLIST (continued)
STEPS
GX300 SECOND STAGE
REGULATOR
FREE FLOW VALVE
KNOB
PROCEDURE
Remove the GX300 second stage regulator from
helmet.
Remove the regulator valve cover and visually
inspect the exhaust valve diaphragm assembly
for damage or deterioration. Clean components
as required. Replace diaphragms if damaged or
deteriorated.
Remove the valve spindle assembly from the
regulator case.
Visually inspect this assembly, then clean it as
required.
Re-set the spindle adjuster to the correct setting
(refer to Apeks GX300 Technical Manual).
When dry, re-install valve spindle assembly into
the regulator case.
Adjust the lever as required and check regula-
tor adjustment (refer to Apeks GX300 Technical
Manual).
Complete the reassembly of the regulator and fit
the regulator back into the helmet.
NOTE: If regulator performance is suspect,
the valve spindle assembly may need to
be disassembled and serviced by a trained
technician.
NOTE: Refer to: Apeks GX300 REGULATOR
FOR THE AQUA LUNG G3000SS DIVING HEL-
MET - MAINTENANCE MANUAL for guidance.
Remove the handwheel knob and check the
condition of the guide hole. It should be square
and firm. If any deterioration or excess play is
present, replace knob.
WARNING: Knob slippage on the stem
may cause dangerous conditions to the
diver, including death.
NOTE: Refer to the free flow / water dump valve
section of the Operations and Maintenance
Manual for guidance.