Aqua Lung G3000SS Operation & Maintenance Manual page 21

Diving helmet
Hide thumbs Also See for G3000SS:
Table of Contents

Advertisement

1. Secure and bleed down the breathing gas supply and the EGS hose.
2. Disconnect all helmet gas connections and disconnect the communication wires
/ cable. Replace hose caps onto hose adapters after removing all water from the
hose adapter.
3. Wash the outside of the helmet and all external fittings completely with fresh
water. This removes dirt and prevents surface corrosion. If required, wash with
soap and water, rinse with fresh water and allow to dry.
4. Visually inspect the helmet fully for damage.
5. Remove the head liner. Visually inspect for damage and/or deterioration. If the
head liner is wet, air dry it.
NOTE: The head liner may be washed as required.
6. If required, and particularly if the inside of the regulator was exposed to salt
or contaminated water, remove the regulator and the oral-nasal mask from
the helmet. Wash with soap and water, rinse with fresh water and allow to dry.
DO NOT allow water to enter the regulator body. Re-install into helmet upon
completion.
NOTE: Refer to the separate Apeks Technical Manual: GX300 REGULATOR
FOR THE AQUA LUNG G3000SS DIVING HELMET - MAINTENANCE
MANUAL for guidance on installation and removal of the regulator.
NOTE: The GX300 regulator valve cover and exhaust valve assembly should be
removed and rinsed carefully with fresh water after diving in extreme conditions
(e.g. sand, sediment, or debris in water).
7. Remove the speakers.
POST-DIVE CHECKLIST (continued)
PROCEDURE
21
INITIALS