Advertisement

Couv
12/08/05
14:33
Page 1
®
F I R S T
T O
D I V E
Regulator
Owner's Manual
Manuel Utilisation
Détendeur
Atemregler
Bedienungsanleitung
Manual de Usuario
Regulador
Gebruiksaanwijzing
Ademautomaten
Aqua Lung France
BP 148
06513 Carros Cedex
Tel 33 - 0- 492.082.888
Fax 33 - 0- 492.082.899
© 2003 Aqua Lung International, Inc.
Doc. N°
125904

Advertisement

Table of Contents
loading

Summary of Contents for Aqua Lung MISTRAL

  • Page 1 Owner’s Manual Manuel Utilisation Détendeur Atemregler Bedienungsanleitung Manual de Usuario Regulador Gebruiksaanwijzing Ademautomaten Aqua Lung France BP 148 06513 Carros Cedex Tel 33 - 0- 492.082.888 Fax 33 - 0- 492.082.899 © 2003 Aqua Lung International, Inc. Doc. N° 125904...
  • Page 2 This owner’s manual is copyrighted, all rights reserved. It may not, in whole or part, be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine readable form without prior consent in writing from Aqua Lung America, Inc. …………………………………………………………………………………………………………………………………………………………………...
  • Page 3: Table Of Contents

    …………………………………………………………… 2. INTRODUCTION ……………………………………………………………………………………………………………………… 2.1. EN Conformity ………………………………………………………………………………………………………… 2.2. Regulator Features ……………………………………………………………………………………………… 2.3. Special features of the MISTRAL twin hose regulator. ………………………………… 2.4. Positions of hoses on the first stage ………………………………………………………………… 2.5. Registered patents ………………………………………………………………………………………………… 3. PREPARATION AND SET UP ……………………………………………………………………………………………………...
  • Page 4: General Precautions & Warnings

    1. GENERAL PRECAUTIONS & WARNING WARNING The Mistral design is different of a single hose regulator due to the double hose and the position of the two stages. That is why, in order to understand the MISTRAL regulator's operating principle and get the best use from it, IT IS CRITICAL THAT YOU TAKE AN IMPORTANT CARE TO READ THIS MANUAL.
  • Page 5: Enriched Air Nitrox Use - Non European Countries

    If you intend to use your new Aqua Lung regulator with EAN (O 2 not to exceed 40%), it is imperative that you maintain the internal cleanliness of the regulator (see section 6 –...
  • Page 6: Introduction

    Before you dive with your new Aqua Lung regulator, it is important to read this manual in its entirety to become familiar with its features, as well as the correct procedures for setup, pre-dive inspection, and post-dive maintenance.
  • Page 7: Special Features Of The Mistral Twin Hose Regulator

    2.3. Special features of the MISTRAL twin hose regulator. The MISTRAL is a two-stage regulator. Its operating principle is exactly the same as that of a single hose regulator: the flow of gas is delivered in two steps from the first stage and then the second stage.
  • Page 8: Positions Of Hoses On The First Stage

    Pressure gauge hose Fitted to a double outlet tank valve Right hand Mistral Regulator The short MP hose configuration (245 mm) is recommended for use with a single outlet cylinder valve. Octopus hose BC inflator hose Pressure gauge...
  • Page 9: Registered Patents

    ...) fitted by your Authorized Aqua Lung Dealer. If you wish to change the MP Hose from the short to the long or visa versa, Aqua Lung also recommends that this be done by your Authorized Aqua Lung Dealer. Your dealer can also answer any questions you may have pertaining to the information in this manual.
  • Page 10: 2Din Or En 144-3 Connections

    AquaLung 1 GB 12/08/05 14:33 Page 10 3.1.2 DIN or EN 144-3 connections 1. Remove the dust cap by unscrewing the DIN wheel. 2. Briefly purge the tank valve by turning the hand wheel to remove any dust or humidity that may remain in the valve.
  • Page 11: Putting The Regulator Under Pressure

    AquaLung 1 GB 12/08/05 14:33 Page 11 7 - Visually check that there is no dust or debris present which could enter the mouthpiece. CAUTION Never try to clean out a foreign body from the mouthpiece using a pointed instrument. 8 - Check that the needle on your submersible pressure gauge is on zero.
  • Page 12: Diving With The Regulator

    It can be difficult to pass your Mistral mouthpiece to another diver. Therefore, Aqua Lung discourages the use of a breathable inflator or any form of alternate breathing where as the diver would be required to give his Mistral mouthpiece to another diver. CAUTION When entering the water by jumping, take care to hold the mouthpiece in your mouth using your hand.
  • Page 13 AquaLung 1 GB 12/08/05 14:33 Page 13 The position of the mouthpiece relative to the second stage diaphragm is essential to avoid free-flows at the surface or in the water when the mouthpiece is not in your mouth: - When the mouthpiece is situated above the second stage diaphragm, the regulator will free-flow.
  • Page 14 AquaLung 1 GB 12/08/05 14:33 Page 14 WARNING DO NOT unscrew the screw connections when adjusting the corrugated hoses. WARNING Do not squeeze the corrugated hoses during the dive, as this will have the effect of reducing the regulator’s respiratory performance. If you have water in the mouthpiece, lean your head to the left and exhale to facilitate evacuation of water.
  • Page 15: Cold Water Diving

    AquaLung 1 GB 12/08/05 14:33 Page 15 5. COLD WATER DIVING WARNING The long MP hose configuration (630 mm) is the one approved for cold water diving according to the EN 250 standard. To avoid the risks of ice formation in the regulator when diving in cold water (water temperature below 50ºF / 10°C), follow at least these recommendations: 1 - Protect your regulator against any accidental entry of water into the 1st or 2nd stages.
  • Page 16 AquaLung 1 GB 12/08/05 14:33 Page 16 CAUTION Do not breathe from the mouthpiece when the regulator is not under pressure. This could damage the diaphragm and/or the valves. NOTE When you disconnect the first stage from the cylinder valve take care that water is not allowed to enter the regulator, particularly via the filter.
  • Page 17: Dealer Inspection & Service

    You must obtain factory prescribed service for your regulator at least once a year from an Authorized Aqua Lung Dealer, regardless of the amount of use it has received. Your regulator may require this service more frequently, depending on the amount of use it receives and the environmental conditions in which it is used.
  • Page 18: Warranty Information

    (30) days of the original purchase. Exchanges will be made through the same Authorized Dealer for Aqua Lung , for merchandise of equal or lesser value, and will be made only for Aqua Lung equipment. Aqua Lung makes this guarantee of satisfaction a part of all product warranties because of the confidence we have in our products.
  • Page 19: Outside Usa & Canada

    Aqua Lung authorized Dealer. • The guarantee covers, at the choice of Aqua Lung, the repair or replacement at our expense of defective parts, in our workshops, transport being at the charge of the pur- chaser.
  • Page 20: Returning Your Regulator For Service - Usa & Canada Only

    Aqua Lung America Warranty program. If you would like to verify whether or not a retail- er is an Authorized Aqua Lung America Dealer, please call or write to Aqua Lung America, Inc.
  • Page 21: Annual Inspection & Service Record

    AquaLung 1 GB 12/08/05 14:33 Page 21 11. ANNUAL INSPECTION & SERVICE RECORD Date Dealer Name Technician Name Observations Stamp Regulator Owner's Manual...

Table of Contents