Aqua Lung G3000SS Operation & Maintenance Manual page 58

Diving helmet
Hide thumbs Also See for G3000SS:
Table of Contents

Advertisement

58
ANNUAL INSPECTION AND MAINTENANCE CHECKLIST (continued)
STEPS
FREE FLOW VALVE
KNOB
DEFOGGER
AIRWAY ASSEMBLY
NOTE: Refer to the manifold section of the Operations and Maintenance Manual for
guidance.
MANIFOLD BODY
CHECK VALVES (2)
O-RINGS (2)
SCREEN
MANIFOLD HOUSING
MANIFOLD GASKET
O-RINGS (2)
TEFLON TAPE
Aqua Lung G3000SS Diving Helmet Operations & Maintenance Manual
PROCEDURE
Check condition of the guide hole in the knob. It
should be square and firm. If any deterioration or
excess play is present, replace knob.
WARNING: Knob slippage on the stem may
cause hazardous conditions for the diver.
Visually inspect the free flow barrel and defogger train
for damage. Replace the o-ring on the swagelock
connector.
Visually inspect the airway assembly.
Clean as required. Blow any moisture out of
airway assembly using compressed air.
MANIFOLD
Remove the manifold body, complete, from
the helmet.
Remove check valves and adapters.
Confirm correct operation of both check valves
by conducting a "suck-and-blow" check on each.
Air should only flow in one direction. If this does
not happen, replace check valve.
Replace o-rings on the manifold and port plugs
annually.
Visually inspect the screen for damage. Wash
with soap and water, rinse with fresh water and
allow to dry.
Visually inspect for damage. Wash with soap and
water, rinse with fresh water and dry by blowing
through with compressed air.
Replace the manifold gasket annually.
Replace o-rings on the manifold connecting insert
annually.
Clean all Teflon tape residue from check valves
and hose fittings. Apply new Teflon tape prior to
reassembly.
INITIALS