Aqua Lung G3000SS Operation & Maintenance Manual page 54

Diving helmet
Hide thumbs Also See for G3000SS:
Table of Contents

Advertisement

54
ANNUAL INSPECTION AND MAINTENANCE CHECKLIST (continued)
STEPS
NOTE: Refer to the neck retainer section of the Operations and Maintenance
Manual for guidance.
LATCH CATCHES
NECK RETAINER
NOTE: Refer to the head liner section of the Operations and Maintenance Manual
for guidance.
HEAD LINER
NOTE: Refer to the nose clearing device section of the Operations and Maintenance
Manual for guidance.
O-RINGS (2)
NEOPRENE PAD
NCD BODY
Aqua Lung G3000SS Diving Helmet Operations & Maintenance Manual
NECK RETAINER AND LOCKING SYSTEM
If required, disassemble both (L and R) latch
catch assemblies.
Inspect all components for damage.
Clean, reassemble and check correct function.
Visually inspect for damage.
Remove neck retainer bolt and replace neck
retainer nut (annually).
HEAD LINER
Remove head liner from helmet.
Visually inspect for deterioration and/or damage.
If necessary, replace with a new liner.
NOTE: The liner may be washed as required.
NOSE CLEARING DEVICE (NCD)
Remove NCD from helmet.
Visually inspect for damage and/or deterioration.
Replace o-rings annually.
Visually inspect for damage and/or deterioration.
If necessary, replace neoprene pad.
Visually inspect for damage to NCD stem.
Confirm ease of movement.
PROCEDURE