ANNUAL INSPECTION AND MAINTENANCE CHECKLIST (continued)
STEPS
FREE FLOW / WATER DUMP VALVE AND DEFOGGER
NOTE: Refer to the free flow / water dump valve and defogger section of the
Operations and Maintenance Manual for guidance.
FREE FLOW / WATER
DUMP VALVE BODY
WATER DUMP EXHAUST
FLAPPER VALVES
O-RINGS (3)
COPPER WASHERS (2)
VALVE SEAT
FREE FLOW / WATER
DUMP VALVE STEM
PROCEDURE
Remove the free flow / water dump valve from
the helmet shell. Disassemble fully and visually
inspect all parts for damage. Clean as required.
Visually inspect for cuts and damage. Wash with
soap and water, rinse with fresh water and allow
to dry. If necessary, replace water dump / exhaust
flapper valve.
NOTE: The flapper valves have a long
service life and are not normally replaced
annually.
Replace all o-rings (3) annually.
Replace both copper washers annually.
Visually inspect and check nylon seat condition.
If necessary, replace entire free flow / water dump
valve seat.
Visually inspect for damage, bends and thread
condition.
If necessary, replace with new valve stem.
57
INITIALS