Aqua Lung G3000SS Operation & Maintenance Manual page 50

Diving helmet
Hide thumbs Also See for G3000SS:
Table of Contents

Advertisement

50
MONTHLY INSPECTION AND MAINTENANCE CHECKLIST (continued)
STEPS
FREE FLOW / WATER
DUMP VALVE
MANIFOLD
HELMET SHELL AND
COMPONENTS
FINAL ASSEMBLY AND
TEST
Signature:
Comments:
Aqua Lung G3000SS Diving Helmet Operations & Maintenance Manual
PROCEDURE
Remove the exhaust valve cover and without
removing the free flow / water dump valve from
the helmet, remove the snap ring and flapper
valve.
Visually inspect flapper valve for damage or
deterioration. Clean flapper valve with soap
and water, rinse with fresh water and allow to
dry. If damaged, replace flapper valve.
Clean the external seating surface on the valve
body (i.e. where the flapper valve makes contact).
NOTE: Refer to the free flow / water dump valve
section of the Operations and Maintenance
Manual for guidance.
Without removing the manifold body from the
helmet, remove the manifold plug and clean the
manifold screen. Replace on completion.
Check both one-way valves for proper operation by
sucking on the umbilical and scuba hose adapters.
NOTE: Refer to the manifold section of the
Operations and Maintenance Manual for
guidance.
Visually inspect the helmet with the above listed
components removed from the helmet.
Verify condition and inspect for damage to the
helmet shell.
Check all o-ring placement surfaces to ensure
proper seal.
Wash the shell with soap and water, rinse with
fresh water and dry with air and towels. Blow
water out of inner airway using compressed air.
Follow procedures in the Operations and Maintenance
Manual to assemble helmet to original condition.
Pressurize the helmet and perform a functional
test and leak check.
Date: