Aqua Lung G3000SS Operation & Maintenance Manual page 55

Diving helmet
Hide thumbs Also See for G3000SS:
Table of Contents

Advertisement

ANNUAL INSPECTION AND MAINTENANCE CHECKLIST (continued)
STEPS
NOTE: Refer to the oral-nasal mask section of the Operations and Maintenance
Manual for guidance.
ORAL-NASAL
INHALATION VALVE
HOUSING
INHALATION VALVE
(one way valve)
NOTE: Refer to the communications section of the Operations and Maintenance
Manual for guidance.
SPEAKER AND
MICROPHONE
COMMUNICATIONS
POSTS
COMMUNICATIONS
TERMINAL BLOCK
PROCEDURE
ORAL-NASAL MASK
Remove oral-nasal mask (microphone must be
remove prior to oral-nasal mask) and check for
damage and/or deterioration.
The oral-nasal mask may be washed as required.
If necessary, replace the oral-nasal mask.
NOTE: The oral-nasal mask has a long service
life and is not normally replaced annually.
Remove and visually inspect for damage. All
spokes of the "wagon wheel" must be present.
If necessary, replace the inhalation valve housing.
Remove and visually inspect for damage and
deterioration.
Replace the inhalation valve annually.
COMMUNICATIONS
Remove and visually inspect the speakers,
microphone, cables and connections. Ensure
that contact surfaces are cleaned thoroughly.
During reassembly check the comms system. If
sound quality is poor, replace speakers and/or
microphone.
Visually inspect for insulation cracks or damage
and re-tighten each nut from inside. Replace
posts as required.
NOTE: There is no requirement to remove
the posts unless damaged.
Visually inspect the internal 4-wire comms terminal
block for damage.
Replace as required.
55
INITIALS