ANNUAL INSPECTION AND MAINTENANCE CHECKLIST (continued)
STEPS
FACE PORT ASSEMBLY
PORT RETAINER
O-RING (1)
FACE PORT
Verify condition and inspect for damage to the helmet shell.
Clean as required with soap and water, rinse with fresh water, and dry.
Blow any moisture out of airway assembly using compressed air.
The reassembly sequence of events is the reverse of disassembly.
Follow Section VI - Step-By-Step Assembly Instructions of the Operations and Maintenance
Manual to reassemble the helmet to original condition.
All components must be clean and fully serviceable prior to assembly.
All o-rings must be lubricated prior to assembly.
Test the helmet after completion of assembly to confirm that it performs correctly
and that there are no leaks.
Signature:
Technician Comments (e.g. Specific items noted during maintenance):
Comments:
PROCEDURE
NOTE: Refer to the face port assembly
section of the Operations and Maintenance
Manual for guidance.
Visually inspect the port retainer and screws for damage.
Clean as required.
Visually inspect the groove for damage and clean
as required.
Replace the o-ring annually.
Check condition of the face port.
If necessary, wash with soap and water, rinse with
fresh water and allow to dry.
Replace the face port if damaged.
NOTE: DO NOT scrub, use aerosol or
chemicals on the face port, it will weaken it.
HELMET SHELL
HELMET REASSEMBLY
HELMET FINAL TEST
Date:
59