14
ACTION
ATTACH THE UMBILICAL
(to be completed by tender)
CHECK THE SECOND
STAGE REGULATOR
(must be completed by diver/tender)
CONFIRM FUNCTION OF
COMMUNICATIONS
(to be completed by diver)
CHECK DRY-SUIT
INFLATION HOSE
(must be completed by tender).
CHECK HELMET FOR
LEAKS
FINAL CHECK
(to be completed by tender)
Signature:
To Diver / Tender: Note comment on the space provided below. Be sure to log maintenance in
the applicable maintenance log.
Comments:
Aqua Lung G3000SS Diving Helmet Operations & Maintenance Manual
DAILY CHECKLIST (continued)
•
Confirm the check valve is properly functioning by
orally checking it (suck on valve to confirm seal).
•
Blow air through the umbilical to remove any debris,
and attach the umbilical into the umbilical adapter
located on the check valve.
•
Slowly depress the purge button to full extent and
confirm a sufficient audible flow of gas.
NOTE: If the regulator free flows, or if after
fully depressing the purge button there is a
weak flow of gas, the regulator needs to be
adjusted or the low pressure valve should be
replaced or serviced by a trained technician.
•
Check all communications to confirm correct
functioning.
•
If fitted, confirm the dry suit inflation valve and
exhaust valve are functioning properly.
•
Apply soap and water to ALL gas fittings and
connections (including the EGS) to check for
leaks on the helmet.
•
Check to ensure the neck retainer is in the correct
position and properly locked.
•
Ensure the diver's safety harness is in good
condition.
•
Ensure the umbilical strain is released.
•
Ensure the EGS hose quick disconnect is in good
condition and is functioning properly.
•
Ensure diver has boots, gloves, knife and other
accessories.
PROCEDURE
Date:
INITIALS