MONTHLY INSPECTION AND MAINTENANCE CHECKLIST (continued)
STEPS
COMMUNICATIONS
NOSE CLEARING
DEVICE (NCD)
ORAL-NASAL MASK
INHALATION VALVE
HOUSING AND
INHALATION VALVE
(one way valve)
Aqua Lung G3000SS Diving Helmet Operations & Maintenance Manual
PROCEDURE
Without removing the comms system, check
condition of speakers and microphone by
visual inspection. If inspection reveals poor
quality of sound, replace with new speakers
and/or microphone.
Without removing them, check communication
posts and terminal block for insulator cracks or
damage. If necessary, replace with new posts.
NOTE: Refer to the communications section
of the Operations and Maintenance Manual
for guidance.
Check NCD for ease of movement and then
remove NCD and check for damage to the
NCD body and components.
Visually inspect o-rings and neoprene pad for
damage and/or deterioration and if necessary
replace. Lubricate o-rings lightly as required.
NOTE: Refer to the nose clearing device
section of the Operations and Maintenance
Manual for guidance.
Remove oral-nasal mask and check for damage
(e.g. splits, cuts, tears) and/or deterioration. No
damage is permitted.
NOTE: If no damage or deterioration is found,
wash oral-nasal mask with soap and water,
rinse with fresh water and allow to dry.
NOTE: Refer to the oral-nasal mask section
of the Operations and Maintenance Manual
for guidance.
Remove and visually inspect both components
for damage and/or deterioration. DO NOT remove
the inhalation valve from the valve housing.
NOTE: All spokes of the "wagon wheel"
must be present.
NOTE: Refer to the oral-nasal mask section
of the Operations and Maintenance Manual
for guidance.
INITIALS