Zone A Maintenance
Temp. integration
Winter delay
Zone A Maintenance
Temp. integration
Summer delta
Zone A Maintenance
Temp. integration
Summer delay
Zone A Maintenance
T.Ext.Set variation
MinTExt S
Zone A Maintenance
T.Ext.Set variation
MaxTExt S
Zone A Maintenance
T.Ext.Set variation
MinTExt Set W
Zone A Maintenance
T.Ext.Set variation
MaxTExt Set W
Zone A Maintenance
T.Ext.Set variation
Mode TExt.W
Zone A Maintenance
T.Ext.Set variation
MinTExt W
Zone A Maintenance
T.Ext.Set variation
MaxTExt W
Zone A Maintenance
T.Ext.Set variation
MinTExt Set W
Zone A Maintenance
T.Ext.Set variation
MaxTExt Set W
Zone A Maintenance
T.Ext.Set variation
Mode TExt.W
Zone A Maintenance
Humid. regulation
COMFORT
Zone A Maintenance
Humid. regulation
ECONOMY
Zone A Maintenance
Humid. regulation
Hysteresis
Zone A Maintenance
Probes calibration
Temperature
Zone A Maintenance
Probes calibration
Humidity
Zone A Maintenance
Probes calibration
Rem. Set.
C-PRO CLIMA SISTEMA INSTALLER MANUAL
Delay on activation of the summer Zone A "integration
to heating" function
(expressed in minutes)
Difference between room temperature and work set-
point due to activation of the summer Zone A
"integration to cooling" function (expressed in °C)
Delay on activation of the summer Zone A "integration
to cooling" function
(expressed in minutes)
Minimum external temperature in summer for summer
Zone A "climatic curve" calculation
(expressed in °C)
Maximum external temperature in summer for summer
Zone A "climatic curve" calculation
(expressed in °C)
Summer work temperature set-point maximum
negative variation for zone A summer "climatic curve"
calculation (expressed in °C)
Summer work temperature set-point maximum positive
variation for zone A summer "climatic curve"
calculation (expressed in °C)
Calculation method of the summer
Zone A "climatic curve":
- DIR. = Direct
- INV. = Inverse
Minimum external temperature in winter for winter
Zone A "climatic curve" calculation
(expressed in °C)
Maximum external temperature in winter for winter
Zone A "climatic curve" calculation
(expressed in °C)
Winter work temperature set-point maximum negative
variation for zone A winter "climatic curve"
calculation
(expressed in °C)
Winter work temperature set-point maximum positive
variation for zone A winter "climatic curve"
calculation
(expressed in °C)
Calculation method of the winter Zone A "climatic
curve"
- DIR. = Direct
- INV. = Inverse
Zone A Comfort time band pre-defined humidity set-
point
(expressed in %r.H.)
Zone A Economy time band pre-defined humidity set-
point
(expressed in %r.H.)
Zone A room humidity regulation hysteresis
(differential) relative to the work set-point
(expressed in %r.H.)
Zone A room temperature probe calibration
(expressed in °C)
Zone A room humidity transducer calibration
(expressed in %r.H.)
Zone A remote set-point variator calibration
(expressed in points)
Page 46
5
1
0.0
0.0
5
1
12.0
0.0
35.0
0.0
-5.0
-10.0
5.0
-10.0
DIR.
DIR.
-5.0
-30.0
12.0
-30.0
5.0
-10.0
-5.0
-10.0
DIR.
DIR.
50.0
0.0
50.0
0.0
5.0
0.0
0.0
-10.0
0.0
-10.0
0
-100
255
10.0
255
60.0
60.0
10.0
10.0
INV.
40.0
40.0
10.0
10.0
INV.
100.0
100.0
99.9
10.0
10.0
100