2.2.2. Details of parameters

The parameters are herein described in details.
(1) NETIP (IP address of robot controller)
The IP address of the robot controller is set. IP address is like the address of the mail.
The format of IP address is composed of 4 numbers of 0 to 255 and the dot (.) between the numbers.
For example, it is set as 192.168.0.1 or 10.97.11.31.
If the controller and network personal computer are directly connected to each other one-to-one, it is allowed to set default
value (a random value) but if it is connected to the local area network (LAN), IP address must be set as instructed by the
manager of customer's LAN system.
If any IP addresses are overlapped, the function will not properly operate. Therefore, take care to prevent it from being
overlapped with another during setting.
The personal computer used for communication with the robot controller.
(2) NETMSK (sub-net-mask )
Set the sub-net-mask of the robot controller. Among the IP addresses, the sub-net-mask is set to define the sub-net-work.
The format of the sub-net-mask is composed of 4 numbers of 0 to 255 and the dot (.) between the numbers.
For example, it is set as 255.255.255.0 or 255.255.0.0.
As usual, it is allowed to set default value. If it is connected to the local area network (LAN), the sub-net-mask must be set
as instructed by the manager of customer's LAN system.
(3) NETPORT (port No.)
The port No. of the robot controller is set. The port No. is like the name of the mail.
For the nine elements, the port numbers are each expressed with a value.
The first element (element No. 1) is used for real-time control.
The second to ninth elements (elements No. 2 to 9) are used for the support software or data link.
Normally, the default value does not need to be changed. Make sure that the port numbers are not duplicated.
(4) CRRCE11 to 19 (protocol)
When using the data link function, the setup is necessary.
Sets the protocol (procedure) for communication. The protocol has three kinds of no-procedure, procedure and data link.
0... No-procedure: The protocol is applied to use the personal computer Support Software .
1... Procedure: Reserved. (Since it is not any function, don't set it by mistake.)
2... Data link: The protocol is used to use OPEN/INPUT/PRINT commands for communication.