Supported Version; Specifications - Mitsubishi Electric CR800 Series Ethernet Function Instruction Manual

Electric industrial robot
Hide thumbs Also See for CR800 Series:
Table of Contents

Advertisement

3 Description of functions

3.6.2. Supported version

Controller type
CR800-R
CR800-D
CR800-Q
Computer support
SW
RT ToolBox3

3.6.3. Specifications

The communication specifications of CC-Link IE Field Network Basic are described below.
3.6.3.1. Communication specifications
The communication specifications of the robot are as follows.
Transmission speed
Communication method
Port number
IP address
Number of occupied stations
Connection cable
CC-Link IE Field version
Maximum
Remote input, RX (*1)
number of link
points
Remote output, RY (*2)
Remote register, RWr (*3)
Remote register, RWw (*4)
(*1) Remote input, RX: Information input from slave to master through bitwise operations.
(*2) Remote output, RY: Information output from master to slave through bitwise operations.
(*3) Remote register, RWr: Information input from slave to master through 16-bit (1 word) operations.
(*4) Remote register, RWw: Information output from master to slave through 16-bit (1 word) operations.
3-82
Version
A1d or later
CR75x-Q and CR75x-D are not supported
A2 or later
Version
1.10L or later
Item
Remarks
Remarks
100Mbps
UDP/IP
61450
192.168.0.20 (initial value, set with NETIP parameters)
Up to four slave stations
Standard Ethernet cable, category 5e or higher (STP cable)
2.00
Number of occupied stations×64 points
Number of occupied stations×64 points
Number of occupied stations×32 points
Number of occupied stations×32 points
Description