2
SETTING UP THE TRANSCEIVERS
Unicast mode operation
■ Registering the transceiver to the RoIP Gateway
4
Open the Bridge Connection screen.
(Bridge Connection Settings > Bridge Connection)
5
In [Bridge Connection], set the connection Source (Example: EXT1), the Bridge Connection Destination
(Custom Bridge Connection), and the IP address of the destination (Example: VE-PG4 in Area B
(192.168.0.2)), then click <Apply>.
• The confi rmation dialogs are displayed. Click <OK> twice to apply them.
L When the bridge connection is set, the Connection Port setting is deleted from the "Destination Settings."
(Destination settings > Destination Settings)
6
In [AMBE+2 Vocoder Assignment], set the Voice Protocol and AMBE+2 Vocoder Assignment, and then
click <Apply>.
L At default, all of the 4 Internal AMBE+2 vocoders are assigned to the digital transceivers. Disable one of the
internal AMBE+2 vocoder to assign it to the EXT1 port.
L If you need an additional AMBE+2 vocoder, an optional CT-24
digital voice converter
2-9
q Confirm
w Enter
e Click
q Select
w Click
is required.