Service mode – coin diagnostics
When a coin is not recognized with 'Service mode' enabled in Fn23, the message INH** is displayed on EAGLE
LCD followed by a number.
Table 3 contains a list of error messages.
INH --
INH 1
Unidentified
INH 2
EAGLE in Exact-Change condition
Euro coin rejected because EAGLE is configured
INH 3
in NCU
nonEuro coin rejected because EAGLE is
INH 4
configured in Euro (=978)
No key has been inserted (but option "Coin
INH 5
No.** with Cashless = Y")
INH 6
Key inserted but cannot be recharged
Key inserted whose credit is higher than the max.
INH 11
credit
Current credit is higher than max. price
INH 12
programmed
Current credit is higher than max. price
INH 13
programmed
INH 14
Key cannot be recharged
Coins are only accepted when a key has been
INH 15
inserted
INH 16
TestServiceKey inserted
INH 17
General ServiceKey inserted (key with blocs, ...) Insert a compatible user key
INH 18
EAGLE in free vend mode
INH 19
Current credit is higher than 65535
Error
Table 3
85
Possible solutions
Check EAGLE configuration
Fn03: check the option
Change = Y/N"
Fn03: check the option "Coin Euro? Y"
Select "N" to accept coins
Fn03: check the option "Coin Euro? N"
Select "Y" to accept coins
Fn03: check the option "Coin No.** with
Cashless? N". Select "Y" to accept coins
Pull out the key and then reinsert it
Fn00: check "Maximum credit cashless=___;
modify the value
Fn04: check "Price max *****"
Fn00: check "Maximum credit with cash=.*****;
modify the value
Fn15: check "Inhibit reload Cashless? Y".
Select "N" to accept
Fn00: check option "Coins only with Key? N".
Select "Y" to accept
Fn15: check option "Coins and bills test?"
Fn07: check time bands for free vends
Limit credit
"Coin no.** Exact-

Hide quick links: