Fn23 - Diagnostics - Paytec Eagle User Manual

Changegiver
Table of Contents

Advertisement

Fn23 – Diagnostics
Service
mode ?
Auto reposition
coin router ?
Test
Separator ?
Ignore errors
separation ?
Validator
error:
Separator
error:
Full sensors
error:
Tube 1
error
Ejector 1
error:
.
N Standard setting.
Y Advanced diagnostics. Error messages are displayed on LCD (see
message list – Table 2).
Automatic repositioning of the swinging coin
N Coin router is repositioned whenever switching the system OFF/ON
(standard)
Y Coin router is repositioned whenever a coin is inserted. The coin router
might be repositioned when pressing the Escrow lever.
N Separator is not tested.
Y Press
to test separator. The separation mechanism will be activated
with a rapid movement.
N Base diagnostics (standard).
Y The separator is not inhibited even if an error has occurred in coin
separation.
Only-read message.
N No errors have been detected.
Y The cashbox sensor might be damaged. If the error is repeated, the
system stops accepting coins (contact Paytec Customer Service).
Only-read message
N No errors have been detected.
Y The separator sensors might be damaged (coins fall in the cashbox).
The message "S" is displayed on the separator LCD.
Contact Paytec Customer Service.
Only-read message.
N No errors have been detected.
Y The sensors "full" might be damaged (positioned on the end of the
separation channels above the coin router). Coins are all routed to the
cashbox. The message "F" is displayed on the selector LCD.
Contact Paytec Customer Service.
Only-read message. Press
N No errors have been detected.
Y A coin has fallen in the wrong tube (that tube is inhibited).
The message "F" is displayed on the selector LCD in the position of the
tube inhibited (contact Paytec Customer Service).
Only-read message. Press
N No errors have been detected.
Y The coin ejector is not in its correct position. The message "E" is
displayed on the selector LCD in the position of the ejector. Check the
puller and try repositioning it (see "Function MOVE"). Switch the system
OFF and ON again. If the error is repeated, contact Paytec Customer
Service.
81
router.
to scroll the list of the six tubes.
to scroll the list of the six ejectors.

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Paytec Eagle

Table of Contents