Diagnostic messages on LCD
Should an error be detected while separating/ejecting a coin, the error is visible in the error list in Fn23 but also
displayed on the selector LCD. Please, check whether there is a coin jam, reset the error and restart your EAGLE.
If the error is repeated, please contact Payment Technologies S.r.l.
Coin unexpected. When such error is detected, the system stops accepting coins until the
U
error is cleared.
Separator failure or coin routed in the wrong tube. The coins that cannot be recognized are
S
routed to the cashbox until the error is cleared.
Tube sensor error (coins are all routed to the cashbox until the error is cleared).
F
Tube entry sensor error or coin routed in the wrong tube (the example refers to tubes B and E).
-F--F-
The error - indicated with letter 'F' - is displayed for the tubes sharing the same optical sensors.
The coins are all routed to the cashbox until the error is cleared.
Ejector sensor error (letter 'E' is displayed on the position where the error was detected).
-E—---
The example refers to an error for ejector B.
Both ejector and tube sensor errors (error displayed on the same position).
-G—---
Resetting errors
A system error can be reset following one of the procedures here below:
1) P6000 .................... Enter Fn23 and set 'Reset errors = Y';
2) Button A ................
3) SETUP keypad .......
Keep 'A' pressed (on tube keypad) and switch the changegiver ON; release 'A'
when the ejector starts moving;
Enter menu 'SETUP' and execute the command 'ErClr'.