Udp Server Mode - 3onedata NP318T-8DI User Manual

Serial device server
Hide thumbs Also See for NP318T-8DI:
Table of Contents

Advertisement

9.4 UDP Server Mode

Background brief
Assuming that the serial port "COM1" of the serial server is operating under "UDP
server mode", passively waiting for one host PC to connect, and the host can read or
send Ethernet data to a serial device. Compared with TCP mode, UDP protocol is
faster and more efficient.
The parameters of the serial server (UDP server) are as follows:
IP Address: 192.168.1.250
Local Port: 30000
BaudRate: 115200
PairtyBits: None
DataBits: 8
StopBits: 1
The parameters of the host PC (UDP client) are as follows:
IP Address: 192.168.1.61
Local Port: 31000
Operation steps
Setp 1 Configure the IP address of the serial server.
1. Log in to the Web configuration interface and select "Network Setting".