Checking Com Information - 3onedata NP318T-8DI User Manual

Serial device server
Hide thumbs Also See for NP318T-8DI:
Table of Contents

Advertisement

Interface Elements
Delimiter
Character Handing
Transmit time
Apply to all Port
"Work mode" and model corresponds to RS232, RS485 and RS422 option.
If there is no matching characters, the data will be sent when the serial data cache is
full of 1460 bytes.

4.2 Checking COM Information

Function Description
On the "COM Information" page, you can view parameter information such as serial
number, alias, baud rate, data bit, stop bit, parity bit and flow control.
Operation Path
Open "Serial server> COM Information" in sequence.
Description
setting value.
If the packet length or forced transmission time is 0 and the
number of delimited characters is greater than 0, the system
will receive the serial data and perform delimiter detection.
Whenever a matching delimited character (or combination
of characters) is received, the system immediately sends all
the cached data to the serial port over the network.
Select the character handling method. The options are:
Retain: The system sends the received delimited
characters along with other data over the network.
Delete: The matching delimited character (or character
combination) will be deleted and the system will only
transfer data other than delimiters.
If the forced transmission time is greater than 0, the system
sends the serial data received within the specified time
through a packet, in the range of 0 to 65535 ms. When the
transfer time is 0, it means that the data transmission
interval is not restricted.
Check the "Apply to all port" check box to apply the current
settings to all serial ports.
3onedata proprietary and confidential
Copyright © 3onedata Co., Ltd.
User Manual
13