3onedata NP318T-8DI User Manual page 41

Serial device server
Hide thumbs Also See for NP318T-8DI:
Table of Contents

Advertisement

Interface Description
UDP rang mode interface screenshot
UDP rang mode interface main element configuration instructions
Interface Elements
Session number
Start address
End address
Dest port
Listen port
Apply to all port
Description
The number of hosts that a serial port is connected at the
same time.
Each host according to the "first in first out" in the order
and serial port communication.
The system supports up to 4 connections.
Enter the start IP address of the UDP rang destination
address.
Enter the end IP address of the UDP rang destination
address.
Enter the port number of the host needs to be connected by
the serial server.
The network receives the listening port of UDP data. The
user must assign a unique listening port to each serial port
so that the system can normally receive UDP data.
Check the "Apply to all port" check box to apply the current
settings to all serial ports.