3onedata NP301 User Manual

3onedata NP301 User Manual

Hide thumbs Also See for NP301:

Advertisement

NP301
User Manual
Date: 2011/11/16 Version 3.1.0
Shenzhen 3onedata Technology Co., Ltd
Http://www.3onedata.com.cn

Advertisement

Table of Contents
loading

Summary of Contents for 3onedata NP301

  • Page 1 NP301 User Manual Date: 2011/11/16 Version 3.1.0 Shenzhen 3onedata Technology Co., Ltd Http://www.3onedata.com.cn...
  • Page 2 Shenzhen 3onedata Technology Co., Ltd Statement Copyright Notice Information in this document is reserved by Shenzhen 3onedata Technology Co.,Ltd. Reproduction and extract without permission is prohibited. Trademarks Notice is registered trademarks of Shenzhen 3onedata Technology Co.,Ltd. All other trademarks or regitered marks in this manual belong to their respective manufacturers.
  • Page 3: Table Of Contents

    Shenzhen 3onedata Technology Co., Ltd Content CHAPTER 1 SUMMARIZE ........................1 1.1 I ............................1 NTRODUCTION 1.2 P ..........................1 RODUCTS EATURES CHAPTER 2 HARDWARE DESCRIPTION ....................2 2.1 P ..........................2 ANEL DESCRIPTION 2.2 I ........................3 NTERFACE DESCRIPTION 2.3 P ......................... 4 OWER SUPPLY DESCRIPTION 2.4 LED I...
  • Page 4: Chapter 1 Summarize

    Chapter 1 Summarize 1.1 Introduction NP301 serial device server is designed to make your serial devices internet ready instantly. It provides 1 port RS232/485/422 (RS232, DB9M; RS485/422, 5 bit terminal block) and 1 port 10/100Base-T(X).It makes them ideal choice for connecting decentral serial devices and Host computer to an IP based Ethernet, making it easily and conviniently for your management.
  • Page 5: Chapter 2 Hardware Description

    Shenzhen 3onedata Technology Co., Ltd Chapter 2 Hardware description 2.1 Panel description Front panel: Top panel: Underside panel:...
  • Page 6: Interface Description

    Shenzhen 3onedata Technology Co., Ltd 2.2 Interface description 10/100Base-T(X) Ethernet port: 2.2.1 The 10/100BaseT(X) ports located on NP302 series front panel. The pin of RJ45 port display as below. Connect by UTP or STP. The connect distance is not more than 100m. 100Mbps is used 100Ωof UTP , 10Mbps is used 100Ωof UTP 3,4,5.
  • Page 7: Power Supply Description

    9~48VDC wide voltage power input, the consumption is about 1.4W 2.4 LED Indicator NP301 has 3 LED Indicator, include Power, Link/ACT, Rx/Tx, the meaning is as follows: Power input steadily: Power LED bright all along Network connect naturally: Link/ACT LED bright all along...
  • Page 8: Chapter 3 Appearance Dimension

    Shenzhen 3onedata Technology Co., Ltd Chapter 3 Appearance dimension Unit:mm...
  • Page 9: Chapter 4 Performace And Parameter

    Shenzhen 3onedata Technology Co., Ltd Chapter 4 Performace and parameter LAN:  Standard: 10Base-T,100Base-TX  Protocol: Support TCP, UDP, APR, ICMP and DHCP protocol  Signal: Rx+,Rx-,Tx+,Tx-  Speed: 10/100Mbps  Working: Full-duplex and half-duplex Working mode: Support Server and Client ...
  • Page 10: Chapter 5 Web Management Function

    NP301 default IP address: 192.168.1.254, subnet mask: 255.255.255.0. When access NP301 through WEB browser. The IP address of the NP301 and PC must be in the same Local Area network. You can modify PC’s or NP301’s IP address to make sure that they are in the same Local Area Network. Operating process can follow method 1 or method 2 as below: Method 1: Modify PC’s IP address.
  • Page 11: Log In Web Interface

    Operation method: 1. Click IE with right key, click “Properties”, empty temporarily files and history record. 2. Open IE, input the IP address of the NP301 in the addressbar, click “Enter”, enter into user name and password interace as figure 5.2.
  • Page 12 3. Input user name and password, “Enter”, enter into NP301 interface as figure 5.3. Web setting interface divide as: 1. Title area 2. Menu bar 3. Setting area. Click menu of the mean bar, can enter into relevant interface, setting area display the status of the NP301 and can configuration. (Figure 5.3)...
  • Page 13 Shenzhen 3onedata Technology Co., Ltd 5.3.1 Device information. Device information included device name, device description, hardware version, software version, MAC address as figure 5.4. Device name Named a different name for each device in the network, it can support Chinese characters, not more than 30 bytes.
  • Page 14 Shenzhen 3onedata Technology Co., Ltd (Figure 5.4) : If it need to set DHCP “automatically obtain IP address”, please ensure DHCP Server is already in the network.and can obtain IP address successfully. After “automatically obtain IP address”, it is need to use...
  • Page 15: Mode Settings

    CtrlBreak default output time (ms) 0-60000 Enter into NP301’s Web interface, click [Serial Setting], choose the required configuration in the corresponding drop-down menu.。Serial settings Web interface as figure 5.5。When NP301 communicate with serial interface device, NP301’s setting is as follows:。...
  • Page 16 8 bits, the standard is 5, 6, 7, 8. Stop bits: The last bit of the single Packet, Typical bit is 1, 1.5 and 2. NP301’s stop bit is 1, 2. Data frames: The frame length that serial interface data convert into Ethernet data, within the range of setting time, it forwardes when data is equal to or longer than the setting frames.
  • Page 17 Setting the vacancy time for connection cut off automatic, if there do not have data transfer, NP301 connection will cut off. If set “0”, means do not care how much time vacancy, NP301 do not cut off voluntary. The range is 1-65535s. Default is 300s The figure below is the configuration interface of TCP Client Mode.
  • Page 18 [Local port] NP301 provide TCP port can be connect by other TCP/IP node, the TCP port have the relationship with the NP301’s relevant seial interface. The figure as follows is TCP Server setting interface, Session 1 set local port is 30000, external TCP port connect NP301through this port.
  • Page 19 Inputing a low level, you can enter AT Command Mode through I/O port trigger. [CtrlBreak trigger] Open Virtual Serial Port, click “Ctrl+PauseBreak”, then open Web page of NP301, click [Operation Settings/AT Command Settings] to enter into AT Commande Mode page. It is enabled by the second way. As Figure 5.9.
  • Page 20 Shenzhen 3onedata Technology Co., Ltd "OK" button. ( Figure 5.10) Choose connecting serial port. Choose connecting serial port under”Connect using”(pay attention to the chosen serial port is consistent with the port connected with the configuration cable) ,Click “OK”。As figure 5.11。...
  • Page 21 Shenzhen 3onedata Technology Co., Ltd (Figure 5.12) As figure 5.13, click again“Ctrl+Break”, at the same time click “Enter” until blinking cursor appears on the screen. In this time you can input AT configuration order through Hyper Terminal. Specific command format and configuration reference 5.5.
  • Page 22: System Tools

    Shenzhen 3onedata Technology Co., Ltd 5.5 System tools System tools menu System tools menu Function Description Restore factory default settings Configuration file File management System upgrade System reset Login settings Modify user name and passwrod 5.5.1 File management The menu included 5 functions: Restore factory default settings, download configuration files, upload configuration files, system upagrde, system restart as figure 5.14:...
  • Page 23 Shenzhen 3onedata Technology Co., Ltd Chocie download configuration files. Click <Download> Choice directory and name to save the files 3. Upnload configuration files Click "System tools" Click "File management" Chocie upnload configuration files. Click <Browse>, Choice the upload files. Click <Upwnload>...
  • Page 24 Shenzhen 3onedata Technology Co., Ltd 5.5.2 User name and password Click [System Tools/Login settings] menu, User can modify the user name and password as figure 5.15: Operation method: 1. Through User name: admin, Password: admin, Enter into WEB interface, Click “Show all” in the function menu, choice user nam and password, enter into login settings interface.