Main element configuration instructions in RealCom Mode interface
Interface Elements
Session number
TCP alive time
Ignore jammed
Cmd type
3onedata proprietary and confidential
Description
The number of hosts that a serial port is connected at the
same time.
Each host according to the "first in first out" in the order
and serial port communication.
The system supports up to 4 connections.
If there isn't any TCP activity within schedule time, the
system will automatically send connection detection
message and check whether the TCP connection is valid. If
the reply packet of opposite side hasn't been received after
sending probe packet for 3 times, system will regard the
opposite
side
communication connection.
Enables or disables ignore jammed connections. The
options are:
Enabled: The system ignores blocked network
connections and continues to send data to other normal
network connections.
Disabled: If the network connection is blocked or the
response is lost, the system will wait until the data is
successfully sent to all network connections before
sending the next data.
Compatible with other companies of the virtual serial port
software. The options are:
Disable: means to use our company's virtual serial port
Copyright © 3onedata Co., Ltd.
as
down
and
forwardly
User Manual
close
the
16