3onedata NP318T-8DI User Manual page 37

Serial device server
Hide thumbs Also See for NP318T-8DI:
Table of Contents

Advertisement

UDP client mode interface main element configuration instructions
Interface Elements
Session number
Dest address
Dest port
Listen port
Queue access
Response timeout
3onedata proprietary and confidential
Description
The number of hosts that a serial port is connected at the
same time.
Each host according to the "first in first out" in the order
and serial port communication.
The system supports up to 4 connections.
Enter the IP address of the host that will be connected by
serial device server.
Enter the port number of the host that will be connected by
serial device server.
The network receives the listening port of UDP data. The
user must assign a unique listening port to each serial port
so that the system can normally receive UDP data.
Enable or disable queue access mode. The options are:
Enabled: Multiple hosts can send or receive data from
the serial port at the same time. The serial server
processes the communication data in the order of FIFO
(first in, first out), prioritizes requests from the first host,
and returns the response to the first host.
Disabled: Means that queue access mode is not
enabled.
Time interval that allows the serial server to respond to each
host's request, the communication between serial server
Copyright © 3onedata Co., Ltd.
User Manual
30

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Np series

Table of Contents