Setting Up Communication Parameters - 3Com SuperStack II PathBuilder S330 Reference Manual

3com wan access switch reference guide
Hide thumbs Also See for SuperStack II PathBuilder S330:
Table of Contents

Advertisement

64
C
3: G
S
HAPTER
ETTING
Setting up
Communication
Parameters
TARTED
To set system clocks, follow these steps:
1 From the System Administration menu, select [4] Manage System Clock to display
the System Clock Configuration menu, shown in Figure 34.
Figure 34 System Clock Configuration Menu
2 Select [3] Set PriorityClock 1 to specify the clock which you want to designate as
the priority 1 (highest priority) clock.
3 Enter the option number corresponding to the clock you want to designate as the
priority 1 system clock. The clock options correspond to the available ports.
If you are configuring a PathBuilder S310, do not select unavailable ports (ports
2-4, CBR ports 2 and 3, and OC3/STM-1) as system clocks—even though the
software lists these ports and allows you to select them.
4 Repeat steps 2 and 3 to designate up to seven additional clocks as the priority 2
through 8 clocks, substituting the appropriate option in step 2. For example, to
designate the priority 2 clock, select [4] Set PriorityClock 2.
5 Select [11] Set System Clock to Highest PriorityClock to set the system clock to the
clock you designated as the priority 1 clock in step 3 above. If this clock fails, the
PathBuilder S330/S310 will automatically use the clock with the next highest
priority as its reference clock.
In order for the PathBuilder S330/S310 to communicate to the Ethernet network,
you must set the correct communication parameters. To do this, select [3] Manage
IP Network Configuration From the System Administration menu, to display the
Manage IP Network Configuration menu, shown in Figure 35, and configure the
following:
Local host IP address
n
Trap client
n
Default gateway
n
The subsections following the figure describe how to set these parameters.