Figure 45 Add Virtual Circuit Menu
3 Build a PVC on the far-end PathBuilder S330/S310, using the MCPU as side A of
the circuit. Set the following parameters on the Add Virtual Circuit screen:
Shaper Number—Choose the number corresponding to the desired shaper
n
value. You assign the shaper number from the MCPU Shapers screen. See
"Configuring MCPU Shapers" in Chapter 4, for details.
IP Address—You must use a different subnet than the one you used for the
n
near-end PathBuilder S330/S310.
Subnet Mask—Specify any acceptable address (for example, 255.255.255.0)
n
VPI/VCI—You must use the same values as you did for the near-end
n
PathBuilder S330/S310.
4 On the Manage IP Network Configuration menu, select [3] Default Gateway
Configuration and set the following:
a Set the default gateway on the far-end PathBuilder S330/S310 to the PVC IP
address you set for the near-end PathBuilder S330/S310 in step 1.
b Set the default gateway on the management station to the local host IP
address of the near-end PathBuilder S330/S310.
For details about setting the default gateway, see "Configuring the Default
Gateway" earlier in this chapter.
5 Apply your IP configuration changes.
a From the main menu, select [1] System Administration.
b From the System Administration menu, select [3] Manage IP Network
Configuration.
c From the Manage IP Network Configuration menu, select [1] Local Host IP
Configuration.
d From the Local Host IP Configuration menu, select [2] Apply IP Configuration
Changes.