Escape Button; The Button Control Module - Federal Signal Corporation SmartSiren Platinum Series Software Manual

Control pad configuration
Table of Contents

Advertisement

Exploring the Interface

Escape Button

The Escape button enables you to cancel your changes in
a pane while returning you to the Lightbar Pane. You can
also use the button to deselect default settings or your saved
settings in a pane with one click.
To cancel your changes in a pane after clicking the Escape
button, click OK in the Saving Button Configuration pop-up.
To keep your selections, click Cancel or the X in the popup.

The Button Control Module

The Button Control Module enables you to select how a button operates when pressed. See also
"Button Control Capabilities" on page 31.
as a Momentary button that turns on a function when pressed and held, and turns off the
function when released.
as a Push On/Off button that turns on a function when
pressed and turns off the function when pressed again.
as an Exclusive button that turns on a function when
pressed and turns off the button that was pressed
previously in the same row.
as a Security Timer that requires the sequential press of
two buttons to turn on a function that turns off after a set
duration. The first button, which is the Security Timer,
must be selected from the buttons with the capability
shown in the table on page 31. The drop-down list of timer
durations has a choice of 4, 8, 12, 16, and 20 seconds.
To turn on the security timer, Button 14, which is the
second "enable" button, must be pressed within 4 seconds
after the first button is pressed. If Button 14 controls
another function, such as a lightbar flash pattern, a second
press of Button 14 turns on the function.
To turn off the Security Timer, press the first button again or let it time out.
as a Timer with a set duration for a function to stay on. The durations are the same as for the
Security Timer.
28
When you click a button in the Button Control Module for the first time,
the legend Esc on the Escape button in the upper right corner of the Device
Selection Module changes from gray to green. The change in color lets you
know that the pane is active and ready for your selections.