Sign In
Upload
Manuals
Brands
Federal Signal Corporation Manuals
Security System
Smart Siren
Federal Signal Corporation Smart Siren Manuals
Manuals and User Guides for Federal Signal Corporation Smart Siren. We have
1
Federal Signal Corporation Smart Siren manual available for free PDF download: Installation And Maintenance Manual
Federal Signal Corporation Smart Siren Installation And Maintenance Manual (52 pages)
Convergence Network
Brand:
Federal Signal Corporation
| Category:
Security System
| Size: 4.25 MB
Table of Contents
Table of Contents
3
Chapter 1 Safety Messages for Installers and Operators
7
Safety Messages to Installers of Federal Signal Sound/Light Systems
7
Safety Messages to Operators of Federal Signal Sound/Light Systems
9
Chapter 2 An Overview of the PA300-CN
11
Siren, PA, and Speakers
11
Lightbars and Signalmaster TM Control
11
Programmable Auxiliary Relays (Model 690200 Only)
11
Programmable Active-Low Inputs
12
Control Pad Features
12
System Specifications
12
Siren Specifications
12
Relay Specifications (Model 690200 PA300-CN Only)
13
PA300-CN Kit Contents
13
Table 2.1 Kit Contents
13
Chapter 3 Connecting the PA300-CN System
14
Selecting Mounting Locations
14
Figure 3.2 Dimensions of the Siren Amplifier
15
Figure 3.1 Dimensions of the Control Pad
15
Figure 3.3 Serial Port Locations on PA300-CN and Connected Devices
17
Figure 3.4 PA300-CN Connection for Model 660100
18
Connections for One or Two Speakers (Cable Assembly P/N 1461907)
19
Figure 3.5 Connections for Two Speakers
19
Connections for Horn Ring Transfer (Cable Assembly P/N 1461907)
20
Figure 3.6 Connections for Horn-Ring Transfer Circuit
20
Figure 3.7 Jumper Setting for GND Activation of HORN RING Circuit
21
Connections for Radio Rebroadcast (Cable Assembly P/N 1461907)
22
Figure 3.8 Connections for Radio Rebroadcast
22
Connections for the Park Input Circuit (Cable Assembly P/N 1461907)
23
Figure 3.9 Jumper Setting for GND Activation of PARK INPUT Circuit
23
Connecting the Active-Low Input Circuits (Cable Assy. 17500063)
24
Connecting the Control Pad
24
Figure 3.10 Connections for the PARK INPUT Circuit
24
Connecting Ignition Power to the Control Pad
25
Connections to the Model 660100 Relay Module/Two-Channel Flasher
18
Preparing to Connect the PA300-CN System
16
Connecting Serial Devices to the Convergence Network
16
Figure 3.12 Network Power Jumper "OFF" Setting
25
Figure 3.14 Standard Microphone Connected to Control Pad
27
Figure 3.15 Remote Microphone Connected to Siren Amplifier
27
Connecting the PA300-CN System to the Battery
28
Connecting Power to the PA300-CN System
28
Preparing to Connect the Power Leads to the PA300-CN System
28
Figure 3.11 Active-Low Input Connections
25
Figure 3.13 Wiring for Ignition Power to Control Pad
26
Connecting the Federal Signal Microphone (P/N 258B8577-03)
27
Connecting the Federal Signal Remote Microphone (Model MNCT-SB)
27
Figure 3.16 Power Connections for Convergence Network
29
Chapter 4 Setting the Gain for Radio Rebroadcast and PA
30
Figure 4.1 Default Control Pad Button for Radio Rebroadcast
30
Setting the Gain for Radio Rebroadcast
30
Figure 4.3 Gain Controls for PA and Radio Rebroadcast (Control Pad)
31
Setting the Gain for Public Address (PA)
32
Figure 4.2 Gain Controls for PA and Radio Rebroadcast (PA300-CN)
31
Chapter 5 Mounting the Siren Amplifier, Control Pad, and MIC
33
Mounting the Siren Amplifier
33
Figure 5.1 Brackets Attached to PA300-CN
34
Figure 5.2 Bracket Attached to Back of Control Pad
35
Mounting the Microphone
36
Mounting the Control Pad
35
Figure 5.3 Brackets Attached to Control Pad and Mounting Surface
36
Figure 5.4 Installation of Microphone Mounting Clip
37
Figure 6.1 Leds and Buttons Associated with Program Mode Settings
38
Dimming or Turning off the Button Leds
39
Entering Program Mode
39
Exiting Program Mode
39
Resetting to the Factory Default Configuration
39
Turning off or on the 10-Second Notification Beep
39
Chapter 6 Setting Control Pad Options
38
Table 6.1 Control Pad Default Configuration
40
Figure 6.2 Default Configuration for Steering Wheel Switches Wired to Control Pad
41
Figure 6.3 LED Programming Indicators on the Control Pad
41
Chapter 7 Control Pad Legends and Safety Messages
42
Applying the Replaceable Control Pad Legends
42
Figure 7.1 Installing the Control Pad Labels
42
Applying the Siren Safety Labels in the Vehicle
43
Distributing the Safety Message Card
43
Figure 7.2 Safety Message Card (Left) and Siren Safety Labels (Right)
43
Chapter 8 Safety Messages to Personnel Servicing Federal Signal Electronic Sirens
44
Chapter 9 Servicing the PA300-CN
45
Replacing the Slide Switch
45
Dismounting and Disconnecting the Control Pad
45
Figure 9.1 Control Pad Removed from Mounting Surface
46
Table 9.2 Control Pad Replacement Parts
48
Table 9.1 PA300-CN Siren Replacement Parts
49
Returning a Product to Federal Signal
50
Figure 9.2 Control Pad Removed from Mounting Brackets
46
Figure 9.3 Slide Switch Removed from Control Pad
47
Replacing the Slide Switch in the Control Pad
47
Getting Technical Support and Service
48
Ordering Replacement Parts
48
Reinstalling the Control Pad
48
Figure 9.4 Interior of the PA300-CN
49
Advertisement
Advertisement
Related Products
Federal Signal Corporation SMART VECTOR SL
Federal Signal Corporation SST-MV
Federal Signal Corporation SSTX3-MV
Federal Signal Corporation SelecTone Series
Federal Signal Corporation Siren A
Federal Signal Corporation Siren L
Federal Signal Corporation SmartSiren Platinum Series
Federal Signal Corporation SmartSystem Load Management System
Federal Signal Corporation SignalMaster 330104 SMC1
Federal Signal Corporation SignalMaster 331105 SMC5
Federal Signal Corporation Categories
Lighting Equipment
Speakers
Security System
Automobile Accessories
Controller
More Federal Signal Corporation Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL