Safety
CAUTION
Improper use of the stance function
Falling due to unexpected product behaviour because of changed damping behaviour.
► Make sure that the patient is standing safely when using the stance function and checks the lock of the knee
joint before placing his/her full weight on the prosthesis.
► Inform the patient whether and in what way the stance function was configured in the adjustment software.
Information on the stance function see Page 63.

4.9 Notes on the safety modes

CAUTION
Using the product in safety mode
Falling due to unexpected behaviour of the product because of changed damping behaviour.
► Observe the warnings/error signals (see Page 74).
CAUTION
Inability to activate safety mode due to malfunction caused by water penetration or mechanical damage
Falling due to unexpected behaviour of the product because of changed damping behaviour.
► Do not continue using the defective product.
► The product must be inspected by an authorised Ottobock Service Centre.
CAUTION
Safety mode cannot be deactivated
Falling due to unexpected product behaviour because of changed damping behaviour.
► If you cannot deactivate safety mode by recharging the battery, a permanent malfunction has occurred.
► Do not continue using the defective product.
► The product must be inspected by an authorised Ottobock Service Centre.
CAUTION
Safety signal occurs (ongoing vibration)
Falling due to unexpected behaviour of the product because of changed damping behaviour.
► Observe the warnings/error signals (see Page 74).
► Do not continue using the product after the safety signal has been emitted.
► The product must be inspected by an authorised Ottobock Service Centre.

4.10 Information on the use of a mobile device with the cockpit app

CAUTION
Improper use of the device
Falling due to altered damping behaviour as a result of unexpected switching into MyMode.
► Use the instructions for use (user) to instruct the patient on proper use of the device with the cockpit app.
CAUTION
Independently applied changes or modifications made to the device
Falling due to altered damping behaviour as a result of unexpected switching into MyMode.
► Do not make any independent changes to the hardware of the device.
► Do not make any independent changes to the software/firmware of the device which are not included in the
update function of the software/firmware.