7.
Updating the parameters
of the frequency converter
Important information
Only the functions described in these repair
instructions can be used in the IndraWorks
software. The user himself must bear res-
ponsibility for any further use. In the event
of non-compliance, Robert Bosch GmbH
does not provide any warranty or liability for
material damages or personal injury.
Furthermore, only the firmware versions and
parameter sets provided by Robert Bosch
GmbH may be used. Robert Bosch GmbH
does not provide any warranty or liability for
material damages or personal injury if solu-
tions from other suppliers are used.
!
Firmware and parameter sets can only be installed
using the BOSCH memory card R 911 298 785.
This is included in parts set 1 687 010 365.
!
Following any change to the frequency converter,
the safety log must be printed out again.
One copy remains with Customer Service for their
personal documentation, one copy is left with the
customer.
Requirements:
R
Notebook with Windows operating system (XP,
Windows Vista oder Windows 7) and serial interface,
or notebook with Windows operating system (XP,
Windows Vista oder Windows 7) and USB port and
USB serial adapter 1 684 465 514.
R
Memory card R 911 298 785
R
Connecting cable R 911 296 708
R
Card reader
R
Installed "IndraWorks" software.
Available on the EDIS DVD (from 2011/2) in "EDIS\
SOFTWARE\KDSOFT\EPS708\INDRAWORKS\SETUP.
EXE".
Memory card and connecting cable are contained in the acces-
1)
sory set 1 687 010 365
Robert Bosch GmbH
Updating the parameters of the frequency converter | EPS 708 | 77
1)
1)
7.1

Updating parameters

7.1.1
Preparatory work
1. Insert Bosch Memory Card in the care reader on the
notebook.
2. Insert "Edis" DVD in CD/DVD drive of the notebook.
3. Open folder "Master 1.2" or higher under 'LW:EDIS\
SOFTWARE\SYSTEMSW\EPS708\PAR_FU_
BOSCHREXROTH' (LW = drive letter of the CD/DVD
drive).
4. Copy all folders to the Bosch Memory Card (do-
cumentation, firmware, set of parameter, Plc and
user). If there are already data on the Bosch Memory
Card, replace them with the new data.
7.1.2
Starting update
1. Switch off the EPS 708.
2. Remove the front cover of the electrical
compartment.
3. Insert Bosch Memory Card (Fig. 146, item 2) in the
memory card slot on the frequency converter
(Fig. 146, item 1). Make sure that the memory card
is positioned correctly.
1
2
Fig. 146: Bosch memory card
1 Control PCB
2 Bosch memory card
4. Switch on the EPS 708.
 The display of the frequency converter shows
Load Par from the MMC
"
i
If an older firmware version (Master 1.0) is installed
on the frequency converter, the message "
re update ?
" is displayed. In this case, start the
update of the firmware by pressing <Enter>
(Fig. 147, item 2). After the firmware has been
updated, the message "
displayed.
en
".
Firmwa-
Load Par fom MMC
" is
|
1 689 975 233