Installing the frequency converter
!
The new frequency converter A13 is supplied with a
parameter set that is designed for the EPS 708.
!
All vents in the frequency converter A13 must be
clear. Do not attach any labels to the vents.
Press the frequency converter A13 (Fig. 125, item 1)
onto the top-hat rail horizontally until it audibly locks
into place.
Fig. 125: Catch for frequency converter A13
Robert Bosch GmbH
Connecting the frequency converter A13
1. Fasten the protective conductor (Fig. 126, item 1)
to the protective conductor bar of the frequency
converter A13. Use the fastening screw screwed into
the frequency converter A13.
1
Fig. 126: Protective conductor connection on the frequency con-
2. Plug the control terminal connector
(Fig. 127, item 1) into the rear control terminal of
the frequency converter A13 from below.
3. Plug the control terminal connector
(Fig. 127, item 2) into the front control terminal of
the frequency converter A13 from below.
Fig. 127: Port of the control terminal