78 | EPS 708 | Updating the parameters of the frequency converter
5. Confirm with <Enter> (Fig. 147, item 2).
 The new parameter set is loaded. After approx.
Load Par from the MMC
30 seconds, "
played on the frequency converter.
6. Confirm by pressing <Enter> (Fig. 147, item 2).
 The safety parameters are loaded. After approx.
1 SS1ES
30 seconds, "
quency converter. The parameters were updated.
7. Switch off the EPS 708.
8. Remove the Bosch Memory Card (Fig. 146, item 2)
from the memory card slot.
1
Fig. 147: <Enter> button on frequency converter
9. Print the safety log (see Section 7.2).
|
1 689 975 233
2018-05-08
" is dis-
" is displayed on the fre-
2
7.2

Printing the safety log

1. Connect the printer to the notebook.
2. Connect the notebook to the frequency converter
using the connecting cable R 911 296 708
(Fig. 148, item 1) with port X2.
1
Fig. 148: Serial connecting cable on frequency converter
3. Switch on the EPS 708.
i
IndraWorks is contained on the EDIS-DVD (as of
2011/2) under "EDIS\SOFTWARE\KDSOFT\EPS708\
INDRAWORKS\SETUP.EXE". Start the file "Setup.
exe" and install the "IndraWorks" software on your
notebook.
4. Start the IndraWorks software.
5. Select "serial connection" in IndraWorks.
6. Select the appropriate COM port.
i
When using the USB serial adapter 1 684 465 514,
you will find the COM port used by the notebook in
the device manager under "ports (COM & LPT)".
7. Select <Advanced ...>.
8. Set baud rate to 9600.
9. Select parity "none".
10. Apply settings with <OK>.
11. Continue connection with <OK>.
 IndraWorks establishes connection with the fre-
quency converter.
12. Check axis designation. The axis designation must
be "
EPS708_M1.2
" or higher.
Robert Bosch GmbH