Replacing The Fan (M2-Ev1) On The Water Chiller - Bosch EPS 708 Repair Instructions

Table of Contents

Advertisement

6.9
Replacing the fan (M2-EV1) on the
water chiller
6.9.1
Disconnect the fan electrically
1. Switch off the EPS 708 at the main switch.
2. Secure the main switch so that it cannot be swit-
ched back on.
3. Unplug the mains plug or disconnect from mains
electricity.
4. Check that there is no power.
5. Remove the front cover of the test oil area.
6. Remove the side cover of the test oil area.
Fig. 51:
Water chiller electrical cabinet
7. Remove the 4 fastening screws of the cover
(Fig. 51, item 1).
8. Remove cover and place it to the side.
i
For an overview of the electrical cabinet compo-
nents, see section 4.8.
9. In the electrical cabinet, remove all covers from all
cable ducts.
10. Disconnect the wires of the fan connection cable
from the following terminals:
Device/terminal
Wire color
KM5/2
Black (BK)
KM5/4
Blue (BU)
KM5/6
Brown (BR)
X1/30
Red (RD), gray (GY) and orange (OG)
PE
Green/yellow (GN/YE)
11. Remove all cable ties.
12. Open the cable gland (see Fig. 15, item 2).
13. Pull the fan connection cable out of the electrical
cabinet.
Robert Bosch GmbH
6.9.2
1. Remove the 4 hex head bolts.
1
Fig. 52:
2. Pull the fan out of the chiller and carefully remove
Fig. 53:
Repair | EPS 708 | 33
Removing the fan
Attachment points
from the test bench.
Fan removal
en
458863-94_Pal
|
1 689 975 233
2018-05-08

Hide quick links:

Advertisement

Table of Contents
loading