8. In the test area of EPS 708, remove the hose assem-
bly from the appropriate connection
(Fig. 142, item 1).
X 2 2
1
Fig. 142: EPS 708 Test area
9. Press <F3>.
10. Select "Venturi" for pressure sensor B48 or "Transfer"
for pressure sensor B49.
11. Confirm query with <F4> and accept selection with
<F12>.
 The pressure value is reset to zero.
12. Exit the window by pressing Esc.
13. Exit the configuration menu by pressing Esc twice.
Robert Bosch GmbH
Repair | EPS 708 | 75
6.40
Changing the workstation light as-
sembly
6.40.1
Workstation light removal
1. Switch off the EPS 708 at the main switch.
2. Open the protective hood.
3. Unplug the mains plug for the workstation light.
4. Remove the cable tie securing the power supply
cable for the workstation light.
5. Remove the mounting plate with the workstation
light.
Fig. 143: Workstation light removal
en
|
1 689 975 233
2018-05-08

Hide quick links: