INSTALLATION
3

3.7.2 Process connections

INFORMATION!
All the procedures that follow are applicable to Metallic Horn and Drop antennas.
Flange connections: installation procedure
Figure 3-10: Flange connections: installation procedure
Ød = nozzle diameter
h = nozzle height
Recommended nozzle size for flange connections
The nozzle must be as short as possible. Refer to the table below for the maximum height of the
nozzle:
Nozzle and antenna diameter,
[mm]
80
100
150
200
1 If the device has antenna extensions, this option extends the maximum nozzle height. Add the length of the antenna
extensions attached to the device to this value.
Equipment needed:
• Device
• Flange gasket (not supplied)
• Wrench (not supplied)
If the antenna diameter is smaller than the process connection size (flange):
• Make sure the flange on the nozzle is level.
• Make sure that you use the applicable gasket for the flange dimensions and the process.
• Align the gasket correctly with the flange facing of the nozzle.
• Put the device carefully on the silo flange. Do not attach the device flange to the silo yet
• Make sure that you point the device in the correct direction. For more data, refer to
notes
on page 28 ("Point the device in the correct direction").
32
Ød
Metallic Horn antenna
[inch]
3
4
6
8
www.honeywellprocess.com
Maximum nozzle height, h
[mm]
[inch]
260
10.24
1
330
12.99
1
490
19.29
1
660
25.98
1
Drop antenna
[mm]
60
1
70
1
100
1
1
34-VF-25-131 iss.1 GLO Feb 2019 US