Honeywell RM640 Handbook page 133

Non-contact radar level meter - 24 ghz radar (fmcw) level transmitter for solids from granulates to rocks
Table of Contents

Advertisement

RM640
Pressure
Pressure
Pressure
Pressure
Process pressure
Other conditions
Other conditions
Other conditions
Other conditions
Dielectric constant (ε
)
r
Ingress protection
Maximum rate of change
Installation conditions
Process connection size
Process connection position
Dimensions and weights
Materials
Housing
Wetted parts, including antenna
Process connection
Gaskets (and O-rings for the
sealed antenna extension option)
Feedthrough
Cable gland
Weather protection (Option)
34-VF-25-131 iss.1 GLO Feb 2019 US
-1...16 barg / -14.5...232 psig
Subject to the process connection used and the process connection temperature.
Guidelines for maximum operating pressure
For more data, refer to
≥1.4
IEC 60529: IP66 / IP68 (0.1 barg / 1.45 psig)
NEMA 250: NEMA type 4X - 6 (housing) and type 6P (antenna)
60 m/min / 196 ft/min
The nominal diameter (DN) should be equal to or larger than the antenna diameter.
If the nominal diameter (DN) is smaller than the antenna, either:
– provide the means to adapt the device to a larger process connection on the tank
(for example, a plate with a slot), or
– use the same process connection, but remove the antenna from the device before
installation and fit it from inside the tank.
Make sure that there are not any obstructions directly below the process
connection for the device. For more data, refer to
For dimensions and weights data, refer to
Polyester-coated aluminium
Option: Stainless steel (1.4404 / 316L) – non-Ex devices only. Ex approvals will be
available in the second quarter of 2018.
Metallic Horn antenna: Stainless steel (1.4404 / 316L)
Drop antenna: PTFE; PP
Stainless steel (1.4404 / 316L)
PTFE Drop antenna:
PTFE Drop antenna:
PTFE Drop antenna:
PTFE Drop antenna:
FKM/FPM (-40...+130°C / -40...+266°F); Kalrez® 6375 (-20...+130°C / -4...+266°F);
EPDM (-50°C...+130°C / -58...+266°F)
PP Drop antenna:
PP Drop antenna:
PP Drop antenna:
PP Drop antenna:
FKM/FPM (-40...+100°C / -40...+212°F); Kalrez® 6375 (-20...+100°C / -4...+212°F);
EPDM (-40°C...+100°C / -40...+212°F)
Metallic Horn antenna:
Metallic Horn antenna:
Metallic Horn antenna:
Metallic Horn antenna:
FKM/FPM (-40...+130°C / -40...+266°F); Kalrez® 6375 (-20...+130°C / -4...+266°F);
EPDM (-50°C...+130°C / -58...+266°F)
PEI (-50...+130°C / -58...+266°F)
This is the maximum range. The feedthrough temperature limits must agree with
the temperature limits of the gasket material and antenna type.
Standard: none
Options: Plastic (Non-Ex: black, Ex i-approved: blue); nickel-plated brass; stainless
steel; M12 (4-pin connector)
Stainless steel (1.4404 / 316L)
www.honeywellprocess.com
TECHNICAL DATA
Installation
on page 25.
Dimensions and weights
1
1
8
on page 139.
on page 141.
133

Advertisement

Table of Contents
loading

Table of Contents