Honeywell RMA300-ME User Manual

Honeywell RMA300-ME User Manual

Remote meter assemblies
Table of Contents

Advertisement

RMA 3000 Remote Meter Assemblies
User Manual
Doc. No.:
34-ST-25-19
Release:
8
Last Revision Date:
July 2017
_________________________________________________________________________________________________________
Honeywell Process Solutions

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell RMA300-ME

  • Page 1 RMA 3000 Remote Meter Assemblies User Manual Doc. No.: 34-ST-25-19 Release: Last Revision Date: July 2017 _________________________________________________________________________________________________________ Honeywell Process Solutions...
  • Page 2 However, we assume no responsibility for its use. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
  • Page 3: Support And Contact Information

    SM and DM meters removed. EU Declaration added. ATEX updated. Support and Contact Information For Europe, Asia Pacific, North and South America contact details, refer to the back page of this manual or the appropriate Honeywell Support web site: Honeywell Corporate www.honeywell.com Honeywell Process Solutions https://www.honeywellprocess.com/*...
  • Page 4 Symbol Definitions The following table lists those symbols used in this document to denote certain conditions. Symbol Definition This CAUTION symbol on the equipment refers the user to the Product Manual for additional information. This symbol appears next to required information in the manual. WARNING PERSONAL INJURY: Risk of electrical shock.
  • Page 5: Table Of Contents

    Contents Support and Contact Information ....................... iii Telephone and Email Contacts ......................iii CE Conformity (Europe) Notice for Remote Meter Assemblies (RMA) ..... vii About Conformity and Special Conditions ..................vii RMA 3000 Description ....................8 Function and Design ..........................8 Meter Types - Options ........................
  • Page 6 Tables Table 1: Certified Engineering Drawings – Wiring Diagrams Table 2: Wiring Overview: ME/ST 3000 transmitter with or without HART Option Table 3: FM Approvals Table 4: Canadian Standards Association (CSA Certification) Table 5: ATEX Approvals Table 6: IECEx Approvals Table 7: South Africa- SAEx S/09-341X Figures Figure 1: Overview of RMA Configuration...
  • Page 7: Ce Conformity (Europe) Notice For Remote Meter Assemblies (Rma)

    CE Conformity (Europe) Notice for Remote Meter Assemblies (RMA) About Conformity and Special Conditions This product is in conformity with the protection requirements of 89/336/EEC, the EMC Directive, and of 94/9/EC, the Explosive Atmospheres (ATEX) Directive. Conformity of this product with any other “CE Mark”...
  • Page 8: Rma 3000 Description

    RMA 3000 Description Function and Design The Honeywell RMA 3000 Remote Meter Assemblies provide various means of remote-mounting a meter that is associated with a Honeywell SmartLine transmitter or a compatible non-Honeywell transmitter. The RMA 3000 includes a remote meter housing that can be used in hazardous environments or in ordinary environments.
  • Page 9: Meter Types - Options

    This manual includes several sets of Honeywell-certified engineering drawings that specify RMA 3000 configurations and conditions that are approved for use in hazardous environments by various approval agencies (FM, CSA, and LCIE (ATEX).
  • Page 10 Function - The Engineering Unit Meter is an LCD indicator that provides a digital display of a transmitter’s output PV when connected in a 4 to 20 mA analog loop. The meter is compatible with Honeywell SmartLine transmitters operating in analog mode and with other non-Honeywell transmitters operating in a 4 to 20 mA current loop.
  • Page 11: Installation In Hazardous Locations

    Installation in Hazardous Locations For installation in hazardous locations, the RMA 3000 must be configured and installed as detailed in the appropriate Honeywell-certified engineering drawing(s), which conform to practices specified by various approval agencies. Installation requirements vary somewhat among approval agencies.
  • Page 12: Specific Parameters Of The Mode Of Protection (Intrinsic Safety)

    (or as intrinsically safe) and of the installation practices used therewith. When installed as intrinsically safe, external wiring shall be in accordance with ordinary location requirements; that is, NEC or CEC or local codes. For information regarding integral installation in Honeywell Smart transmitters refer to the following publications. ST 3000 Smart Pressure transmitters...
  • Page 13 ST 3000 Smart Temperature transmitters EN1I-6190_Feb11 STT 3000 - Series STT250 Temperature transmitter, Models STT25H, STT25D, STT25M. STT25T, STT25S Operator Manual EN1I-6190_Mar10 STT 3000 - Series STT250 Temperature transmitter, Models (Legacy) STT25H, STT25D, STT25M. STT25T Operator Manual Release 8 RMA 3000 Remote Meter Assemblies User Manual...
  • Page 14: Approvals For Specific Configurations - Certified Drawings

    Each of these specific configurations has been documented by Honeywell in controlled Engineering Drawings that are certified by Honeywell and approved by the appropriate body (FM, CSA, and ATEX). Copies of the certified drawings are included in this publication at the end of this section.
  • Page 15: List Of Certified Engineering Drawings - Wiring Diagrams

    List of Certified Engineering Drawings – Wiring Diagrams The certified and approved engineering drawings available for specific applications in hazardous locations are listed in Table 1. Some of the drawings include details of integral mounting of the meter in transmitters, in addition to that for remote meter mounting. Table 1: Certified Engineering Drawings –...
  • Page 16 Application Document Description Drawing Number For intrinsically safe application (CSA) Interconnection Diagram, RMA3000 50029789 Remote Meter – CSA (Supersedes Sheet 1 of 51450806) 51450806 Lightning Protection Option Sheet 2 – Communicator Sheet 3 – RMA 300 - ME (Analog Meter) Sheet 6 –...
  • Page 17: Wiring Drawings - Overview

    The wiring drawings included in the following tables are included in this manual to provide a quick reference for interpreting the information given in the Honeywell-certified engineering drawings referenced in the tables. These simplified drawings are intended for use along with certified engineering drawings to indicate the similarities / differences among various wiring configurations.
  • Page 18: Table 2: Wiring Overview: Me/St 3000 Transmitter With Or Without Hart Option

    Table 2: Wiring Overview: ME/ST 3000 transmitter with or without HART Option With Lightning Protection Option; Drawings: Without Lightning Protection Option; Drawings: 51204241-3 (FM) 51204241-7 (FM) 51204242-3 (CSA) 51204242-7 (CSA) 51204243-3 (ATEX) 51204243-6 (ATEX) 51205784-4 (FM – HART) 51205784-7 (FM – HART) 51450805-6, -7 (CSA –...
  • Page 19: Installation In Non-Hazardous Locations

    CSA and ATEX include only configurations that include a single meter (ME or EU) with a single Honeywell ST 3000 Pressure transmitter. However, the Honeywell remote meter housing provides a convenient means of connecting multiple meters to a single transmitter in non-hazardous locations.
  • Page 20: Appendix A - Product Certifications

    Manual, which supports the ATEX certifications for this product. CE Conformity The Honeywell RMA 3000, Models RMA300, ME and EU Remote Meter Assemblies are in conformity with the protection requirements of the following European Council Directives: 94/9/EC, the Explosive Atmospheres (ATEX) Directive, and 2004/108/EC, the EMC Directive.
  • Page 21: Marking And Inscriptions

    ATEX Directive 2014/34/EU. The following information is provided as part of the labeling of the transmitter:  Name and Address of the manufacturer: Honeywell, Fort Washington, PA 19034, USA  Notified Body identification: DEKRA Quality B.V., Arnhem, the Netherlands ...
  • Page 22 Nameplate 50031953-001, ia, is mounted on the enclosure. The following is a representation of this nameplate: Nameplate 50031954-001, nA (Zone 2), is mounted on the enclosure. The following is a representation of this name plate: RMA 3000 Remote Meter Assemblies User Manual Release 8...
  • Page 23 The RMA 3000, Models RMA300, ME & EU Remote Meter Assemblies are Special conditions for intrinsically safe apparatus that can be installed in potentially explosive atmospheres. safe use, Intrinsic Safety (X) The power terminals (+, -) must be connected only to a certified associated intrinsically safe apparatus.
  • Page 24: A1. European Directive Information (Ce Mark)

    A1. European Directive Information (CE Mark) RMA 3000 Remote Meter Assemblies User Manual Release 8...
  • Page 25 Release 8 RMA 3000 Remote Meter Assemblies User Manual...
  • Page 26 RMA 3000 Remote Meter Assemblies User Manual Release 8...
  • Page 27: Hazardous Location Wiring

    Hazardous Location Wiring North America Class I, Division 1 and Group II, Zone 1 Requirements: Wiring shall be in accordance with the applicable portions of the National Electrical Code, ANSI/NFPA 70 (NEC), for the United States, the Canadian Electrical Code, CSA C22.1 (CEC), for Canada. NEC.
  • Page 28 European Union and Countries That Follow ATEX/IECEx Practices: Cables for Fixed Apparatus shall be thermoplastic sheathed cables, thermosetting sheathed cables, elastomeric sheathed cables, or mineral insulated metal sheathed cables for fixed wiring. Cables for fixed wiring shall have flame propagation characteristics that enable them to withstand the tests according to EN 60332-1-1 and EN 60332-1-2.
  • Page 29: A3. Hazardous Locations Certification

    G; Class III, Division 1, T4, Ambient Temperature = 40 C maximum, when connected in accordance with Honeywell drawing 50034080. Non-incendive for use in Class I, Division 2, Groups A, B, C & D; Suitable for Classes II & III, Division 2, Groups F &...
  • Page 30 RMA 3000 Remote Meter Assemblies User Manual Release 8...
  • Page 31: Table 4: Canadian Standards Association (Csa Certification)

    G; Class III, Division 1, T4, Ambient Temperature = 40 C maximum, when connected in accordance with Honeywell drawing 50029789. Suitable for use in Class I, Division 2, Groups A, B, C & D; Suitable for Classes II & III, Division 2, Groups F &...
  • Page 32 RMA 3000 Remote Meter Assemblies User Manual Release 8...
  • Page 33: Table 5: Atex Approvals

    ATEX Approvals Table 5: ATEX Approvals Code Description Flameproof: LCIE 02ATEX6177X II 2 G Ex d IIC Gb T6 (Ta= -40 to +65°C), T5 (Ta= -40 to +85°C) II 2 D Ex tb IIIC Db T95°C (Ta= -40 to +65°C) orT80°C (Ta= -40 to +85°C) Intrinsically Safe: LCIE 02ATEX 6178X II 1 G Ex ia IIC Ga T4 (Ta= -40°...
  • Page 34: Table 6: Iecex Approvals

    IECEx Approvals Table 6: IECEx Approvals Code Description Certificate: LCI 08.0034X Flameproof: Ex d IIC Gb T6 (Ta= -40 to +65°C), T5 (Ta= -40 to +85°C) Ex tb IIIC Db T95°C (Ta= -40 to +65°C) orT80°C (Ta= -40 to +85°C) Intrinsically Safe: Ex ia IIC Ga T4 (Ta= -40°...
  • Page 35: Table 7: South Africa- Saex S/09-341X

    SAEx Table 7: South Africa- SAEx S/09-341X Code Description Intrinsically Safe: Ex ia IIC T4 (Ta = -40°C to +85°C), T5 (Ta = -20°C to +60°C) Flameproof: Ex d IIC T6 (Ta = -20°C to +65°C), T5 (Ta = -40°C to +85°C) SAEx Intrinsic Safety Entity Parameters Ui = 30 V Ii = 100 mA...
  • Page 36 Fax: +(822) 792 9015 Specifications are subject to change without notice. For more information To learn more about RMA3000 visit www.honeywellprocess.com Or contact your Honeywell Account Manager Process Solutions Honeywell 1250 W Sam Houston Pkwy S Houston, USA, TX 77042...

This manual is also suitable for:

Rma 3000Rma300-euRma300-smRma300-dm

Table of Contents