Honeywell RM640 Handbook page 93

Non-contact radar level meter - 24 ghz radar (fmcw) level transmitter for solids from granulates to rocks
Table of Contents

Advertisement

RM640
Menu No. Function
C5.1.3 Device Information
C5.1.3.1
Descriptor
C5.1.3.2
Message
C5.1.3.3
Date
C5.1.3.4
Cfg. Change
Counter
C5.1.4 HART Variables
C5.1.4.1
Current Out. 1
Var.
C5.1.4.2
HART/sec./CO2
Var.
C5.1.4.3
Tertiary Var.
C5.1.4.4
Quaternary Var.
C6 Display
C6.1
Language
C6.2
Backlight
34-VF-25-131 iss.1 GLO Feb 2019 US
Function description
You can give a short description (16
characters maximum) of the device in this
menu item.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: Operator
setting:
setting:
setting:
You can give more data in this menu item
(32 characters maximum).
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: Operator
setting:
setting:
setting:
You can enter the date in this menu item
(Format: Year-Month-Day / YYYY-MM-DD)
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting: Operator
setting:
setting:
This function counts the number of changes
to the HART® device settings
This is the first measurement type shown on
HART® controllers. Make a selection from
the list.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: Expert
setting:
setting:
setting:
This is the second measurement type shown
on HART® controllers. Make a selection
from the list.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: Expert
setting:
setting:
setting:
This is the third measurement type shown
on HART® controllers. Make a selection
from the list.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting:
setting: User
setting:
setting:
This is the fourth measurement type shown
on HART® controllers. Make a selection
from the list.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: User
setting:
setting:
setting:
Data can be shown in one of the languages
stored in the device. Make a selection from
the list.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: User
setting:
setting:
setting:
If you set this menu item to "Enabled", a
light comes on when you push a button on
the display keypad and if the loop current is
more than 6 mA.
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
Minimum access level to change the
setting: User
setting:
setting:
setting:
www.honeywellprocess.com
OPERATION
Selection list
Read only
Level, Distance, Sensor
Value, Reflection
2
Level, Distance, Sensor
Value, Reflection
2
Level, Distance, Sensor
Value, Reflection
2
Level, Distance, Sensor
Value, Reflection
2
English, German,
French, Italian,
Portuguese, Spanish,
Czech, Polish, Chinese
(simplified), Japanese,
Russian, Turkish
Disabled, Enabled
6
Default
2014-01-01
Level
Level
Reflection
Sensor Value
English
Enabled
93