Honeywell RM640 Handbook page 85

Non-contact radar level meter - 24 ghz radar (fmcw) level transmitter for solids from granulates to rocks
Table of Contents

Advertisement

RM640
Menu
Function
No.
B1.2 Output
B1.2 Output
B1.2 Output
B1.2 Output
B1.2.1
Current Output 1
B2 Actual Values
B2.1
Operating Time
[s]
B2.4
Level
B2.5
Distance
B2.6
Reflection
B2.7
Level Lin.
B2.8
Volume
B2.9
Mass
B2.10
Distance Lin.
34-VF-25-131 iss.1 GLO Feb 2019 US
Function description
This sets analogue output 1 to a test
value [mA]. Output will change to the
selected value, independent of the
measured value.
When you push [^ ^ ^ ^ ] to confirm the
value, the display shows the question
"Start Simulation?" Push [ ] or [ ] to
set the display to "Yes". Push [^ ^ ^ ^ ] again
to start the test. The device goes to
back to Normal mode after 1 hour.
Minimum access level to do the
Minimum access level to do the
Minimum access level to do the
Minimum access level to do the
procedure: Expert
procedure:
procedure:
procedure:
This is the total time that the device is
energized in seconds.
This menu item shows the level
readings measured at this time. This
measurement data is shown with the
units set in menu C7.5 Units
C7.5 Units.
C7.5 Units
C7.5 Units
This menu item shows the distance
readings measured at this time. This
measurement data is shown with the
units set in menu C7.5 Units
C7.5 Units.
C7.5 Units
C7.5 Units
This menu item shows the percentage
of the emitted radar signal which
makes a reflection on the surface of
the silo contents and is received by the
device. If the distance measured is less
than 1 metre, then the reflection value
is 0%.
This menu item shows the level
readings (linearized) measured at this
time. This measurement data is shown
with the units set in menu C7.5 Units
This menu item is only available if you
set up a linearization table in menu
item C3.1 Edit Table
C3.1 Edit Table.
C3.1 Edit Table
C3.1 Edit Table
This menu item shows the volume
readings measured at this time. This
measurement data is shown with the
units set in menu C7.5 Units
C7.5 Units. This
C7.5 Units
C7.5 Units
menu item is only available if you set
up a conversion (volume) table in menu
item C3.1 Edit Table
C3.1 Edit Table.
C3.1 Edit Table
C3.1 Edit Table
This menu item shows the mass
readings measured at this time. This
measurement data is shown with the
units set in menu C7.5 Units
C7.5 Units. This
C7.5 Units
C7.5 Units
menu item is only available if you set
up a conversion (mass) table in menu
item C3.1 Edit Table
C3.1 Edit Table.
C3.1 Edit Table
C3.1 Edit Table
This menu item shows the distance
readings (linearized) measured at this
time. This measurement data is shown
with the units set in menu C7.5 Units
This menu item is only available if you
set up a linearization table in menu
item C3.1 Edit Table
C3.1 Edit Table
C3.1 Edit Table
C3.1 Edit Table.
www.honeywellprocess.com
Selection list
3.6...21.5 mA
Read only
Read only
Read only
Read only
Read only
C7.5 Units.
C7.5 Units
C7.5 Units
Read only
Read only
Read only
C7.5 Units.
C7.5 Units
C7.5 Units
OPERATION
6
Default
1
85

Advertisement

Table of Contents
loading

Table of Contents