TECHNICAL DATA
8
cQPSus
- pending
NEPSI
- pending
Other standards and approvals
Other standards and approvals
Other standards and approvals
Other standards and approvals
Electromagnetic compatibility
Radio approvals
Electrical safety
NAMUR
CRN
Construction code
1 Kalrez® is a registered trademark of DuPont Performance Elastomers L.L.C.
2 HART® is a registered trademark of the HART Communication Foundation
3 T* = T5 or T4. For more data, refer to the related Ex approval certificate.
4 T*°C = 100°C or 130°C. For more data, refer to the related Ex approval certificate.
5 T* = 100°C or 130°C. For more data, refer to the related Ex approval certificate.
136
Division ratings
Division ratings
Division ratings
Division ratings
XP-IS, Class I, Div 1, GPS ABCD, T6...Tx;
DIP, Class II, III, Div 1, GPS EFG, T85°C...T*°C ;
IS, Class I, Div 1, GPS ABCD, T6...Tx;
IS, Class II, III, Div 1, GPS EFG, T85°C...T*°C;
NI, Class I, Div 2, GPS ABCD, T6...Tx;
NI, Class II, III, Div 2, GPS FG, T85°C...T*°C
Zone ratings
Zone ratings
Zone ratings
Zone ratings
Class I, Zone 1, AEx db ia [ia Ga] IIC T6...T* Gb (US) – antenna suitable for Zone 0;
Ex db ia [ia Ga] IIC T6...T* Gb (Canada) – antenna suitable for Zone 0;
Class I, Zone 0, AEx ia IIC T6...T* Ga (US);
Ex ia IIC T6...T* Ga (Canada);
Zone 20, AEx ia IIIC T85°C...T*°C Da (US);
Ex ia IIIC T85°C...T*°C Da (Canada);
Zone 21, AEx ia tb [ia Da] IIIC T85°C...T*°C Db (US) – antenna suitable for Zone 20
Ex ia tb [ia Da] IIIC T85°C...T*°C Db (Canada) – antenna suitable for zone 20
Ex ia IIC T*~T6 Ga/Gb;
3
Ex d ia IIC T*~T6 Ga/Gb;
3
Ex iaD 20/21 T85...T* IP6X;
Ex iaD 20/21 tD A21 IP6X T85°C...T*°C
EU: Electromagnetic Compatibility directive (EMC)
EU
EU
EU
EU: Radio Equipment directive (RED)
EU
EU
EU
FCC Rules
FCC Rules
FCC Rules: Part 15
FCC Rules
Industry Canada: RSS-211
Industry Canada
Industry Canada
Industry Canada
EU: Agrees with the safety part of the Low Voltage directive (LVD)
EU
EU
EU
USA and Canada
USA and Canada
USA and Canada: Agrees with NEC and CEC requirements for installation in
USA and Canada
ordinary locations
NAMUR NE 21 Electromagnetic Compatibility (EMC) of Industrial Process and
Laboratory Control Equipment
NAMUR NE 43 Standardization of the Signal Level for the Failure Information of
Digital Transmitters
NAMUR NE 53 Software and Hardware of Field Devices and Signal Processing
Devices with Digital Electronics
NAMUR NE 107 Self-Monitoring and Diagnosis of Field Devices
Pending. This certification is applicable for all Canadian provinces and territories.
For more data, refer to the website.
Option: ASME B31.3
www.honeywellprocess.com
4
4
4
3
4
5
4
RM640
3
4
34-VF-25-131 iss.1 GLO Feb 2019 US