AT commands
Default
0

Q1 (P1 Timeout)

Specifies how long pin P1 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0

Q2 (P2 Timeout)

Specifies how long pin P2 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0

PT (PWM Output Timeout)

Specifies how long both PWM outputs (P0, P1) output a given PWM signal before it reverts to the
configured value (M0/M1). If set to 0, there is no timeout. This timeout only affects these pins when
they are configured as PWM output.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0xFF
Diagnostics – Firmware/Hardware Information
The following AT commands provide information about the XBee3 DigiMesh RF Module hardware and
firmware.

VR (Firmware Version)

Reads the firmware version on a device.
Parameter range
0x3000 - 0x30FF [read-only]
Default
Set in the firmware