AT commands
For all other LT values, the firmware measures LT in 10 ms increments.
Parameter range
0, 0x14 - 0xFF (x 10 ms)
Default
0

CB (Commissioning Button)

Use CB to simulate Commissioning Pushbutton presses in software.
You can enable a physical commissioning pushbutton with
Configuration).
Set the parameter value to the number of button presses that you want to simulate. For example,
send CB1 to perform the action of pressing the Commissioning Pushbutton once.
Parameter range
1, 2, 4
Parameter
Description
Keeps device awake for 30 seconds.
1
2
Nominate the node as the sleep coordinator for synchronous sleep networks.
Restore defaults (equivalent to sending an
4
Default
N/A

I/O sampling commands

The following commands configure I/O sampling on an originating device. Any I/O sample generated
by this device is sent to the address specified by DH and DL. You must configure at least one I/O line as
an input or output for a sample to be generated.

IS (I/O Sample)

Immediately forces an I/O sample to be generated. If you issue the command to the local device, the
sample data is sent out the local serial interface. If sent remotely, the sample data is returned as a
Command Response frame -
If the device receives ERROR as a response to an IS query, there are no valid I/O lines to sample.
Parameter range
N/A
Default
N/A
Digi XBee3® DigiMesh 2.4 RF Module User Guide
0x88.
I/O sampling commands
D0 (DIO0/ADC0/Commissioning
RE (Restore
Defaults)).