Ricoh Da-P1 Field Service Manual page 49

Machine code: m187
Table of Contents

Advertisement

8.
Exit the SP mode.
SP5-816-208 Error Codes
Cause
Operation Error,
Incorrect Setting
Code
Meaning
-1200
Inquiry, registration attempted
2
without acquiring Request No.
-1200
Attempted registration without
3
execution of a confirmation and
no previous registration.
-1200
Attempted setting with illegal
4
entries for certification and ID2.
-1200
@Remote communication is
5
prohibited. The device has an
Embedded RC gate-related
problem.
-1200
A confirmation request was made
6
after the confirmation had been
already completed.
-1200
The request number used at
7
registration was different from the
one used at confirmation.
-1200
Update certification failed
8
because mainframe was in use.
-1200
The ID2 in the NVRAM does not
9
match the ID2 in the individual
certification.
-1201
The certification area is not
0
initialized.
Settings for @Remote Service
Solution/ Workaround
Obtain a Request Number
before attempting the Inquiry
or Registration.
Perform Confirmation before
attempting the Registration.
Check ID2 of the mainframe.
Make sure that "Remote
Service" in User Tools is set to
"Do not prohibit".
Execute registration.
Check Request No.
Check the mainframe
condition. If the mainframe is
in use, try again later.
Check ID2 of the mainframe.
Initialize the certification
area.