SC No.
Level
SC990-00
D
SC No.
Level
SC991-00
C
SC No.
Level
SC992-00
D
Error Name/Error Condition/Major Cause/Solution
Software performance error
The software attempted to make an unexpected operation.
• Incorrect argument
• Incorrect internal parameter
• Insufficient working memory
• Abnormal performance caused by an error that cannot be detected
in normal SC detection due to hardware specifications.
• Turn the main power off/on.
• Reinstall the software of the controller board.
• Reinstall the software of the engine board.
Error Name/Error Condition/Major Cause/Solution
Software continuity error
The software has attempted to perform an unexpected operation.
(However, the process can continue running if recovery processing is
carried out.)
• Incorrect argument
• Incorrect internal parameter
• Insufficient working memory
• May have resulted from an error that cannot be detected by the
hardware using normal SC detection.
Logging only.
Error Name/Error Condition/Major Cause/Solution
Undefined SC error
An error that is not controlled by the system occurred (the error does not
come under any other SC code).
A SC code used in the previous machine was applied erroneously.
Turn the main power off/on.