002 Bit Switch 2 Settings
bit 0
DFU
bit 1
DFU
bit 2
DFU
bit 3
[PCL5e/c,PS]: PDL Auto Switching
Enables/Disables the MFPs ability to change the PDL processor mid-job.
Some host systems submit jobs that contain both PS and PCL5e/c. If Auto PDL
switching is disabled, these jobs will not be printed properly.
bit 4
DFU
bit 5
DFU
bit 6
DFU
bit 7
DFU
1001
[Bit Switch]
003 Bit Switch 3 Settings
bit 0
DFU
bit 1
DFU
bit 2
[PCL5e/c]: Legacy HP compatibility
Uses the same left margin as older HP models such as HP4000/HP8000.
In other words, the left margin defined in the job (usually "<ESC>*r0A") will be
changed to "<ESC>*r1A".
bit 3
DFU
bit 4
DFU
bit 5
DFU
bit 6
DFU
bit 7
DFU
1001
[Bit Switch]
Printer Service Mode
0
1
-
-
-
-
-
-
Enabled
Disabled
-
-
-
-
-
-
-
-
0
1
-
-
-
-
Disabled
Enabled
-
-
-
-
-
-
-
-
-
-