Ricoh Da-P1 Field Service Manual page 270

Machine code: m187
Table of Contents

Advertisement

6. Troubleshooting
SC No.
SC998-00
268
Level
Error Name/Error Condition/Major Cause/Solution
Application start error
• After power on, no application program is registered to the system
within a predetermined period of time. (No application starts or ends
normally.)
• Even if they are started, all applications have become unable to be
rendered due to an unknown defect.
• Software bug
D
• An option required by the application (RAM, DIMM, board) is not
installed properly
• Turn the main power off/on.
• Check whether an option required by the application (RAM, DIMM,
board) is installed properly.
• Check whether downloaded applications are correctly configured.
• Replace the controller board.